Page 5-24
MDE-4334C Atlas Start-up and Service Manual · April 2008
Pump Programming
Programming 8800 Series Units
To program the pump, proceed as follows:
1
Press
12
.
2
Enter the Side # where 1 = Side A, 2 = Side B.
3
Enter the Function Code (1-4).
4
Enter the Configuration Code.
Function Code 1: Two-wire Pump ID
Sets the two-wire ID that the POS uses for the dispenser/pump involved. Press
Enter
after
making selections.
1-16 = Choose a number between 1-16
Function Code 2: Cash/Credit At Pump
0 = No
2 = Yes
Function Code 3: Side Exists
0 = Does not exist
1 = Exists
Function Code 4: PPU Options
0 = Level 1 price bar displays the level sent by console
1 = Normal
Level 3 Programming
You must enter Level 1 and 2 before accessing Level 3 commands.
•
Level 1 -
Press
Fl
, enter the 4-digit ID (default 2222), then press
Enter
.
•
Level 2
- From Level 1, enter any Level 2 Command Code (10-12), enter the 4-digit ID
(default 1503), and then press
Enter
.
•
Level 3
- From Level 2, enter any Level 3 Command Code (13-17), enter the 4-digit ID
(default 1309), and then press
Enter
. Press
F1
to exit any command code. Press
F2
to
return to normal operation.
Command Code 13: Pin Code Change
Change PIN code.
To change the PIN code, proceed as follows:
1
Enter
13
.
2
Enter Level #1, 2 or 3.
3
Enter the new PIN Code.
Note: The unit returns to Command Input Mode.