MDE-4334C Atlas Start-up and Service Manual · April 2008
Page 5-17
Programming 8800 Series Units
Pump Programming
To perform a Master Reset, proceed as follows:
1
Record all totals and programming. Isolate the unit at the D-Box.
2
Shut off power to the unit.
3
Install a jump jack on JP-1B on the A side main display (junction box opening side).
4
Restore power to the unit and wait for Error Code 40.
5
Remove the jump jack.
6
Reprogram the unit.
7
Bring the unit back on line at the D-Box.
Level 1 Programming
The following information gives specific programming steps for Level 1 commands. All this
information is entered on the Manager Keypad. Ensure that you follow the steps shown. The
side with the junction box opening is Side 1 while the other side is Side 2. Power-up and
Command Code 8 will display the current software version.
For Level 1 programming, proceed as follows:
1
Press
Fl
.
2
Enter the 4-digit ID (default 2222); then, press
Enter
.
3
Press
F1
to exit any command code.
4
Press
F2
to return to normal operation.
You may enter any command code directly from Level 1 after entering the PIN code.
Command Code 1: Program PPU
Manual programming of PPU, unit pricing. Pricing can also be downloaded via the two-wire
communication using the POS device.
To program the PPU, proceed as follows:
1
Press
1
and then press
Enter
.
2
Select the Side (1 or 2) and then press
Enter
.
3
Select the Grade and then press
Enter
.
4
Select the Price Level and then press
Enter
.
5
Enter the new PPU and then press
Enter
.
Note: Repeat the above steps for the other Side, Grade, and Price Level.