MDE-4334C Atlas Start-up and Service Manual · April 2008
Page 5-19
Programming 8800 Series Units
Pump Programming
Command Code 5: Test Customer Programmable Preset
Test Programmable Customer Preset is a code that is used to initiate testing for the Five-button
Preset option if used.
To program the Test Programmable Customer Preset, proceed as follows:
1
Press
5
and then press
Enter
.
2
Select the Configuration and then press
Enter
, where:
0 = STOP Test/Program
1 = START Test/Program
Depending upon the preset option, the type testing will convey the following when you press
the preset buttons:
Five Button Preset (Non-Customer Programmable Preset)
Press
Enter
after making selections, where:
1 = Program Button 1 (Default 1)
2 = Program Button 2 (Default 5)
3 = Program Button 3 (Default 10)
4 = Program Button 4 (Default 15)
Incremental Preset (Non-Customer Programmable Preset)
Press
Enter
after making selections, where:
1 = Program Button 1 (Default 1) Money
2 = Program Button 2 (Default 5) Money
3 = Program Button 3 (Default 10) Money
4 = Program Button 1 (Default 1) Volume
5 = Program Button 2 (Default 5) Volume
6 = Program Button 3 (Default 10) Volume
After the test is complete, follow programming steps to setup.
Command Code 6: Memory Clear For Error Code 31 or 35
The Memory Clear code is only useful to clear a unit displaying an Error Code (EC) 31 Totals
Data Error) or EC 35 Configuration Data Error.
To program the Memory Clear code, proceed as follows:
1
Press
6
and then press
Enter
.
2
Press
1
and then press
Enter
.
Command Code 7: Program Totals Input
The Setting Totals Input code allows setting of non zero totals. It is useful for new installations
or service when the station does not want to restart totals for its dispensers at zero, when old
dispensers are replaced, or receive certain types of service. It can only be performed after
performing a Master Reset, CC7, or for new units.