MDE-4334C Atlas Start-up and Service Manual · April 2008
Page 5-13
Programming 8800 Series Units
Pump Programming
Programming 8800 Series Units
For 8800 series units, the programming mode can only be entered when both sides of the
dispenser are in an idle mode, using the Manager Keypad. The nozzles must be in the nozzle
boots. Dispenser programming results in the unit being placed offline with regard to external
communications. Dispenser programming is started by pressing
F1
on the Manager Keypad.
The following sub-sections describe general dispenser operation while in programming mode.
At each level, the PIN code must be entered. Once you are in the third level, you can access
any programming process.
General Programming Details
Action
Cash Display
LSD in Volume
Display
F1
1
2222
0000
1
ENTER
Repeats for Level 2
88888 Flashing
10
10
ENTER
2
1503
0000
2
ENTER
Repeats for Level 3
88888 Flashing
17
17
ENTER
3
1309
0000
3
ENTER
88888 Flashing
Notes:1) It is important to note that each programming level utilizes a unique set of
programming codes. The reason for this is to allow room for future expansion of
programming features. Function codes within a command code begin at 1.
2) Once the highest level security code has been entered, you can access all levels.
Entry into a command code will present data in either the DEFAULT format or last
programmed values for that command code. Only one command code and function code/
parameter may be programmed/changed at a time.
on
shows a PCA of the Gasboy 8800 Electronic System. For proper
service, the technician must be knowledgeable of the functions of components and how they
relate to the system.