MDE-4334C Atlas Start-up and Service Manual · April 2008
Page 6-39
Power Supplies
Electronic and Electrical Components
Power Supplies
About Power Supplies
The function of the power supply is to provide clean voltage at correct values required by the
electronics.
Replacing Fuses
Using an incorrectly sized fuse may cause equipment damage. To ensure equipment protection and
maintenance of safe operation, always use the correct replacement fuse.
CAUTION
shows the ATC retail Atlas Cable # M02739A001 from T20092-G1 Pump
Controller (PCA) P205 (16) and 207 (10) to T20569 G1 OP ATC PCA P405 (34) and P301
(20) and 305 (34).
Figure 6-31: M02739A001 Cable
To T20569-G1 P305 (32)
J301 To T20569-G1 P301 (20)
J405 To T20569-G1 P405 (34)
J205 To T20092-G1 P205 (16)
To T18994-G1 P305 (16)
J207 To T20092-G1 P207 (10)
J307 To T18994-G1 P307 (10)
J305
P305
M04659A001 Cable
Connector #
via Cable
to Assembly
at Connector #
J405 (34)
M02739A001
T20569-G1
P405 (34)
P305 (16)
M02739A001
T18994-G1
P305 (16)
J205 (16)
M02739A001
T20092-G1
P305 (34)