MDE-4334C Atlas Start-up and Service Manual · April 2008
Page 4-13
Preventive Maintenance Table
Preventive Maintenance and Inspection
Nozzle hooks
and shafts
Every six months
1
Lubricate with silicone spray, if needed.
2
Check for damage.
3
Verify if the locking tab locator is not broken (The locking tab locator
helps hold the nozzle in the nozzle boot and enables the station
owner to lock the nozzle boot with a clasp padlock).
4
If repair is needed, call an ASC to make the repairs.
WARNING
The pump/dispenser contains pressurized flammable fuel and lethal
voltages.
Servicing a Gasboy Atlas unit incorrectly could result in severe injury or
death.
Do
not
attempt to service the Gasboy Atlas pump/dispenser yourself, and
do
not
allow untrained personnel to service Gasboy Atlas pumps/
dispensers. Only Gasboy Atlas-trained ASCs should service a Gasboy
Atlas unit.
• Owner—
Inspect
• ASC only—
Repair and test
Mechanical
computers
Every six months
5
Lubricate well. See Veeder-Root manuals for lubrication points.
WARNING
The pump/dispenser contains pressurized flammable fuel and lethal voltages.
Servicing a Gasboy Atlas unit incorrectly could result in severe injury or death.
Do
not
attempt to service the Gasboy Atlas pump/dispenser yourself, and do
not
allow untrained personnel to service Gasboy Atlas pumps/dispensers.
Only Gasboy Atlas-trained ASCs should service a Gasboy Atlas unit.
ASC only
Door locks
Every six months or
if the door locks
become difficult to
open and close
Lubricate with a graphite lubricant or lock oil. Follow the manufacturer’s
instructions. Do
not
over-lubricate. Use a rag to wipe any excess lubricant
that may drip.
Owner
Tank
Every 6 months
Monitor water levels in the tank with an electronic tank monitor or water
detection pasted on the tank measuring stick.
Owner - Inspect
Water in Tank
After every fuel tank
fill-up
Remove with a sump pump.
1
Gasboy recommends shutting off power to the unit before performing
these inspections and process.
2
Block off the pump/dispenser to prevent customers from operating
the pump/dispenser during procedure.
3
Access and insert the sump pump into the tank and draw off the
water.
• Owner—
Inspect
• ASC only—
Repair and test
Components
Recommended
Frequency
Recommended Maintenance
Who Performs the