Page 7-24
G1000 System Maintenance Manual
Rev. A
190-00903-00
7.1.8 GTX
33/33D
Original GTX Reinstalled:
No software or configuration loading is required if the original GTX is reinstalled. This does not
include units that were returned for repair as their software and configuration files are deleted
during the repair testing process.
New or Repaired GTX Installed:
If a new or repaired GTX is installed, load the following files after removing the Supplemental
Database cards from the bottom slots of each display. Note which card was removed from the
MFD so it may be identified later for reinsertion in the MFD when software and configuration
loading is complete. It contains a FliteChart or Chartview database which is only used in the
MFD. Reinstall all the cards after the software and configuration file loads are complete.
GTX1 Software
•
GTX2 Software
•
GTX1 Configuration
•
GTX2 Configuration
After loading software and configuration files, turn to the Transponder Configuration page and
enter the Registration (Address) and Flight ID numbers.
7.1.8.1 GTX 33/33D Testing
If unit is removed or replaced the following tests are recommended:
The integrated transponder/altitude reporting system must be verified in accordance with Title 14
of the Code of Federal Regulations (CFR) §§ 91.411 and 91.413.
Transponder Ramp Test
This test requires the use of a Mode S ramp generator. Specific instructions for operating the
ramp tester are contained in the applicable operator's manual. Refer to Title 14 CFR Part 43
Appendix F for testing criteria.