____________________________________________________________________
G1000 System Maintenance Manual
Page 5-27
190-00903-00
Rev.
A
GIA2/GMA 1347D #2 data path is functioning correctly.
GIA2/GMA 1347D #2 data path is not functioning
correctly.
•
Check PFD1 Alert Window for GIA or GMA
configuration or software error messages. Correct
any errors before proceeding.
•
Verify GMA #2 status is OK using the AUX -
SYSTEM STATUS PAGE on the MFD. If it has a
Red-X, troubleshoot why the GMA is offline before
proceeding.
•
Swap GMA 1347D #1 and GMA 1347D #2,
reconfigure both GMA’s to their new locations to
confirm if the problem is in the original GMA 1347D
#2.
−
Replace original GMA 1347D #2 if box turns
green after swapping units.
•
Swap GIA1 and GIA2, reconfigure both GIA’s to
their new locations to confirm if the problem is in
the original GIA2.
−
Replace original GIA2 if box turns green after
swapping units.
•
Check the GIA2/GMA 1347D #2 interconnect
wiring and connector pins for faults.
CHNL 7
GMA
1347D #2
GIA1/GMA 1347D #2 data path functionality is
unknown. Reload GIA2 configuration files.