G1000 System Maintenance Manual
Page 5-55
190-00903-00
Rev.
A
Advisory Message
Possible Cause
Recommended Actions
GMA XTALK – GMA crosstalk
error has occurred.
The G1000 has detected an
error in the communication
between GMA 1347D #1
and
GMA 1347D #2.
•
Ensure both units are receiving
power.
•
Ensure both units are
configured.
•
Check interconnect wiring and
connector pins for faults.
•
Replace GMA 1347D #1 with a
known good unit.
•
If problem persists, reinstall
original 1347D #1 and replace
GMA 1347D #2.
BACKUP PATH – Audio panel
using backup data path.
The GMA 1347 is using a
backup RS-232 data path.
•
Troubleshoot for a failed
datapath using Section 5.1.5.