____________________________________________________________________
G1000 System Maintenance Manual
Page 5-63
190-00903-00
Rev.
A
PFD2 CONFIG – PFD2
configuration error. Config
service req’d.
The G1000 has detected a
PFD #2 configuration
mismatch.
•
Reload PFD 2 Configuration
files including optional
equipment configuration files
that list PFD 2 in the
PRODUCT box on the System
Upload page.
•
Press the UPDT CFG softkey
on the Configuration Upload
Page in the System Page
Group to load configuration files
into the configuration module.
•
Check PFD1 configuration
module wiring for faults and
replace if necessary.
•
Replace PFD1 configuration
module.
•
Replace the PFD2.
NOTE
New Terrain/Obstacle cards,
Jeppesen Aviation Database and
other optional features (i.e. TAWS
unlock card) will need to be
replaced if the master configuration
module is changed. The G1000
System ID number will change to a
new number when installing a new
master config module. The old
Terrain and other cards will no
longer work as they will remain
locked to the old System ID
number.