5.1.8.7 GEA Configuration Page
CAUTION
The data contained on the GEA Configuration Page (Figure 5-18) is
extremely critical to aircraft safety. Although the content can be viewed,
the technician cannot make changes unless authorized and equipped to do
so.
Figure 5-12. GEA Configuration Page
These pages show configuration settings for all inputs/outputs of the GEA 71 Engine/Airframe
Unit. All settings are pre-established for a particular installation and are loaded from the
appropriate G1000 Loader Card. Input/Outputs are categorized by groups and are brought on-
screen by the pressing appropriate softkey. All settings are contained in the ‘GEA 1’
configuration file.
GEA
―
This box indicates which GEA, GEA circuit board, and/or GEA I/O channel is currently
selected for display.
DATA
―
This box displays current configuration settings for the selected inputs/outputs in the
GEA window.
SOFTKEYS
:
a.
ANLG/CRNT
―
Displays analog/current configuration settings.
b.
ANLG IN
―
Displays analog in configuration settings.
c.
CRNT MON
―
Displays current monitor configuration settings.
d.
ENG TEMP
―
Displays engine temperature sensor configuration settings.