Table 6-3: Shutdown Fault Definitions Cont.
Shutdown Condition
Description
Action
Low Oil Pressure
Oil pressure < alarm set point
Check oil pressure and for sources
of high system pressure
High Plant Delivery Temp
Plant delivery temp > alarm set
point
Check plant delivery temp or
reduce package power
High Plant Temp Rate
Rapid temp rise of plant temp
detected
Check plant temp or reduce
package power
High Interstage Temp
Interstage Temp > alarm set point
Check Interstage temp or reduce
package power
High Interstage Temp Rate
Rapid temp rise of Interstage temp
detected
Check Interstage temp or reduce
package power
High Control Box Temp
Control box temp > alarm set point
Check control box temp or reduce
package power
High Oil Temperature
Oil injection temperature > alarm
set point
Check oil temperature
DIN Low Oil Level 1
Digital input for Oil Level 1 has
tripped
Check oil level 1
DIN Low Oil Level 2
Digital input for Oil Level 2 has
tripped
Check oil level 2
Open EXP XD1
Connection to expansion module
PIN1 is open
Check wiring between expansion
module PIN1 and controller
Shorted EXP XD1
Connection to expansion module
PIN1 is shorted
Check wiring between expansion
module PIN1 and controller
Open EXP XD2
Connection to expansion module
PIN2 is open
Check wiring between expansion
module PIN2 and controller
Shorted EXP XD2
Connection to expansion module
PIN2 is shorted
Check wiring between expansion
module PIN2 and controller
Open EXP XD3
Connection to expansion module
PIN3 is open
Check wiring between expansion
module PIN3 and controller
Shorted EXP XD3
Connection to expansion module
PIN3 is shorted
Check wiring between expansion
module PIN3 and controller
Open EXP XD4
Connection to expansion module
PIN4 is open
Check wiring between expansion
module PIN4 and controller
Shorted EXP XD4
Connection to expansion module
PIN4 is shorted
Check wiring between expansion
module PIN4 and controller
Open EXP XD5
Connection to expansion module
PIN5 is open
Check wiring between expansion
module PIN5 and controller
Shorted EXP XD5
Connection to expansion module
PIN5 is shorted
Check wiring between expansion
module PIN5 and controller
Open EXP TT1
Connection to expansion module
TIN1 is open
Check wiring between expansion
module TIN1 and controller
Shorted EXP TT1
Connection to expansion module
TIN1 is shorted
Check wiring between expansion
module TIN1 and controller
Open EXP TT2
Connection to expansion module
TIN2 is open
Check wiring between expansion
module TIN2 and controller
Shorted EXP TT2
Connection to expansion module
TIN2 is shorted
Check wiring between expansion
module TIN2 and controller
Open EXP TT3
Connection to expansion module
TIN3 is open
Check wiring between expansion
module TIN3 and controller
Shorted EXP TT3
Connection to expansion module
TIN3 is shorted
Check wiring between expansion
module TIN3 and controller
Open EXP TT4
Connection to expansion module
TIN4 is open
Check wiring between expansion
module TIN4 and controller
Shorted EXP TT4
Connection to expansion module
TIN4 is shorted
Check wiring between expansion
module TIN4 and controller