5.1.4.6 Auto Restart
Accessibility
Maintenance
Distributor
Factory
The next item in the
Timer Setpoints
menu is the
Auto Restart
function. If
Auto Restart
is enabled,
the compressor will resume operation in the mode it was in prior to the power interruption when
power is restored. The default value for
Auto Restart
is disabled.
Automatic restarting of the compressor can cause injury or death
5.1.4.7 Auto Restart Delay
Accessibility
Maintenance
Distributor
Factory
The next item in the
Timer Setpoints
menu is the
Auto
Restart Delay
value, which controls how
long the compressor will wait to start after power has been restored. This parameter is only available
if the
Auto Restart
feature is enabled.
Min Value: 5 seconds
Max Value: 300 seconds
Default Value: 10 seconds
5.1.4.8 Start Timer
Accessibility
Maintenance
Distributor
Factory
The following item in the
Timer Setpoints
menu is the
Start Timer
.
The
Start Timer
is used to
extend how long the compressor will run in the pause state before it is allowed to start modulating.
Min Value: 0 seconds
Max Value: 600 seconds
Default Value: 0 seconds
5.1.4.9 Stop Timer
Accessibility
Maintenance
Distributor
Factory
The
Stop Timer
is the next item in the
Timer Setpoints
menu. When the STOP button is pressed or
a remote stop is activated, the compressor will blow down and the motor(s) will continue to run until
this timer expires.
Min Value: 0 seconds
Max Value: 120 seconds
Default Value: 5 seconds