13-17-613 Page 67
Table 6-2: Advisory Fault Definitions Cont.
Advisory
Description
Action
DIN Motor Overtemp
Digital input programmed for Motor
Over Temperature has tripped
Check main motor(s) temperature
or reduce package power
DIN Water Pressure
Digital input programmed for
Water Pressure has tripped
Check water pressure
DIN High Vibration
Digital input programmed for High
Vibration has tripped
Check for source of vibration
Motor Lube Timer
Motor lubrication interval timer has
expired
Lubricate motor(s) and reset timer
CBOX Filter Timer
Control box filter change interval
timer has expired
Change or clean control box air
filter element
Oil Sample Timer
The maintenance timer for taking
an oil sample has expired
Take an oil sample and reset the
timer
DIN User Alarm
Digital input programmed for User
Alarm has tripped
Check User alarm
Low Oil Pressure
Oil pressure < alarm set point
Check oil pressure
High Interstage Temp
Interstage Temp > alarm set point
Check Interstage temp or reduce
package power
High Plant Delivery Pres
Plant Delivery Pressure > alarm
set point
Check air cooler functionality or
reduce package power
High Control Box Temp
Control Box Temp > alarm set
point
Check control box temp or reduce
package power
High Oil Temperature
Oil injection temperature is > alarm
set point
Check oil temperature or reduce
package power
DIN Oil Level 1
Digital Input oil level 1 has tripped Check oil level 1
DIN Oil Level 2
Digital input oil level 2 has tripped
Check oil level 2
High Differential Temp
Differential temp > alarm set point
Check differential temp or reduce
package power
High Discharge Pressure
Discharge pressure > alarm set
point
Check discharge pressure
High Inlet Pressure
Inlet pressure > alarm set point
Check inlet pressure
Low Oil Level 1
Oil sump level 1 < alarm set point
Oil level low; add oil to sump #1
Low Oil Level 2
Oil sump level 2 < alarm set point
Oil level low; add oil to sump #2
High Enclosure Temp
Enclosure temperature exceeded
alarm set point
Check enclosure ventilation fan for
proper operation
High Oil Temp 1
Oil temperature #1 > alarm set
point
Check oil level or reduce package
power
High Oil Temp 2
Oil temperature #2 > alarm set
point
Check oil level or reduce package
power
6.2 Shutdown Faults
The shutdown faults in the AirSmart G2 controller are designed to protect the compressor from
component failure or extreme environmental conditions. Shutdown faults can be reset after the
compressor has stopped by pressing the STOP button. If the error condition still exists, the shutdown
fault cannot be reset. The status of the compressor at the time of each shutdown is stored in non-
volatile memory, which can be accessed through the history menu.