13-17-613 Page 63
5.4.8.8 Sequence Time Offset
Accessibility
Maintenance
Distributor
Factory
Sequence Time Offset
increases the number of hours a compressor will report it has to other
compressors in the network. This can be used to synchronize maintenance schedules between
multiple machines.
5.4.9 Oil Control Setup
The
Oil Control Setup
menu allows the user to set oil control method, oil control parameters, aftercooler
temp rise, and target temperature adjust.
The
Oil Control Setup
menu structure is organized as follows:
Caution
: These parameters are not available in all compressor packages and should not be adjusted
unless directed by Gardner Denver unit control personnel.
5.4.9.1 Oil Control Method
Accessibility
Maintenance
Distributor
Factory
The
Oil Control Method
allows the distributor and factory user to define one of the following for the
oil control method: none, injection, or delta T. Depending on which method is defined, there will be
different parameters that can be changed corresponding to that oil control method.
5.4.9.2 Oil Control Parameters A-G
Accessibility
Maintenance
Distributor
Factory
The
Oil Control Parameters A-G
allows the distributor and factory user to define the value of the
seven different oil control parameters. These oil control parameters are different depending on which
O
i
l Control Method
is selected. When selecting one of the oil control parameters, the parameter
that is being changed will be labeled above the keypad that is shown. When the
Oil Control Method
selected is
none
, the oil control parameters can be ignored as their values will not be applicable for
that method.
Table 5-4 below shows what each parameter controls when either the injection or delta T oil control
method is selected.