13-17-613 Page 71
Table 6-3: Shutdown Fault Definitions Cont.
Shutdown Condition
Description
Action
Open EXP TT5
Connection to expansion module
TIN5 is open
Check wiring between expansion
module TIN5 and controller
Shorted EXP TT5
Connection to expansion module
TIN5 is shorted
Check wiring between expansion
module TIN5 and controller
DIN Enclosure Temp
Digital input for enclosure temp
has tripped
Check the enclosure temperature
and associated wiring
High Discharge Pressure
Discharge pressure > alarm set
point
Check discharge pressure or
sources of high pressure
High Inlet Pressure
Inlet pressure > alarm set point
Check inlet pressure
Low Oil Level 1
Oil sump level 1 < alarm set point
Oil level low; add oil to sump #1
Low Oil Level 2
Oil sump level 2 < alarm set point
Oil level low; add oil to sump #2
High Oil Level 1
Oil sump level 1 > alarm set point
Oil level high; check oil in sump #1
High Oil Level 2
Oil sump level 2 > alarm set point
Oil level high; check oil in sump #2
Low Ambient Temp
Ambient temp < alarm set point
Locate blower to area with ambient
temperature > 32°F (0°C)
High Differential Temp
Differential temp > alarm set point
Check differential temp or reduce
package power
High Differential Temp Rate
Rapid temp rise of differential temp
detected
Check differential temp or system
functionality
High Enclosure Temp
Enclosure temp > alarm set point
Check enclosure temp or reduce
package power
High Oil Temp 1
Oil temperature #1 > alarm set
point
Check oil level or reduce package
power
High Oil Temp 2
Oil temperature #2 > alarm set
point
Check oil level or reduce package
power
High Oil Temp Rate
Rapid temp rise of Oil temp
Check oil temp or system
functionality