Installation guide

Remote VLT® Control Panel LCP 601 and Mounting

Kit

VLT® Soft Starter MCD 600

1 Overview

1.1 Description

The remote VLT® Control Panel LCP 601 can be mounted up to 3 m (9.8 ft) away from the soft starter. The LCP is rated IP65 when
mounted correctly in accordance with these instructions.

The LCP connects to the soft starter via the DB9 connector on a hardware expansion card. A hardware expansion card must be installed
to use the remote LCP with the soft starter. Separate kits are available with a dedicated LCP connector expansion card, or with no
expansion card for applications already using another smart card.

1.2 Parts List

Item

Quantity

Remote VLT® Control Panel LCP 601

1

LCP connector expansion card (selected kits)

1

Cable, DB9

1

Gasket, foam

1

Installation guide

1

M3 x 16 screw

4

M3 flat washer

4

M3 spring washer

4

M3 nut

4

Jack screw

4

Table 1: Ordering Numbers

Kit

Ordering number

Remote VLT® Cotrol Panel LCP 601 and Mounting Kit

175G0134

AN265232431650en-000101 / 175R1177 | 1

Danfoss A/S © 2018.06

Summary of Contents for VLT LCP 601

Page 1: ...n card must be installed to use the remote LCP with the soft starter Separate kits are available with a dedicated LCP connector expansion card or with no expansion card for applications already using...

Page 2: ...e the soft starter while the expansion port cover is open may endanger personnel and can damage the soft starter Be careful when installing the expansion cards and make sure not to touch the inside th...

Page 3: ...gasket is compressed to half its original thickness torque approximately 1 Nm 8 8 in lb NOTICE If the screws are too long the gasket does not provide IP65 protection Overtightening the screws can dam...

Page 4: ...croll through the status screens 5 Local control keys 2 Status LEDs 4 Shortcut to the command source menu in Set up Tools 6 Shortcut keys for quick access to common tasks Logs Open the Logs Menu Graph...

Page 5: ...is set to Remote LCP removing the remote LCP causes a trip 2 4 Mounting Diagram Drill 4 mounting holes for screws 1 in each corner and 2 holes for the DB9 connector NOTICE The image is not to scale D...

Page 6: ...45 in 13 mm 0 5 in 13 mm 0 5 in 136 mm 5 35 in 142 mm 5 6 in Illustration 2 Drilling Template Installation Installation guide Remote VLT Control Panel LCP 601 and Mounting Kit AN265232431650en 000101...

Page 7: ...3 Jack screw 5 Spring washer 7 VLT Control Panel LCP 601 9 Panel 2 Screw 4 Flat washer 6 Nut 8 Gasket 10 Cable Illustration 3 Exploded View Installation Installation guide Remote VLT Control Panel LC...

Page 8: ...der provided that such alterations can be made without subsequential changes being necessary in specifications already agreed All trademarks in this material are property of the respective companies D...

Reviews: