The inflation / deflation continues as long as the button is held. The display shows the current height
(relative to the standard height) while valves are activated in order to help see the height change and
also confirm the behaviour of height sensors.
The suspension can be returned to normal operations by choosing ‘EXIT&LEAVE TEST MODE’ or
pressing the
button.
All except L322-02.
The EAS ECU will also return to normal operations when the vehicle is driven or
by using the raise or lower switch (centre console) of the air suspension to change height mode.
L322-02.
If the option ‘EXIT&KEEP TEST MODE’ was chosen, normal EAS operations must be re-