Ref / Pt.No: 294130
Operating Instructions for Safe Use
Fullwood M²erlin
Revision: C
Date: 24-Mar-17
294130
Page 74 of 81
75
error
COW_FOLLOWE
R_ERROR
The cow follower application has
reported an errror.
Error will be
generated, milking
will be terminated
and system will be
set to pause mode.
The cow follower
application has reported
an errror.
Check cow follower and
reset alarm.
76
error
COW_FOLLOWE
R_NO_COW
The cow follower isn't seeing a
cow anymore.
Disabled/not used while cow can
be out of sight at the front or the
back.
N/A
The cow follower isn't
seeing a cow anymore.
Disabled/not used while
cow can be out of sight
at the front or the back.
N/A
77
error
ARM_PLC_
COMMUNICATIO
N
No communication between the
Festo PLC and the UCC.
Fatal alarm will be
generated in case
arm is in the box.
An error will be
generated in case
arm is outside the
box.
No communication
between the Festo PLC
and the UCC.
Check system and reset
alarm.
78
warning
NO_SYSTEM_
COMMUNICATIO
N
No communication/timeout
between the HMI and the main
UCC.
Warning will be
generated.
No
communication/timeout
between the HMI and
the main UCC.
Check system.
79
warning
ARM_NO_
CONFIGURATIO
N
The ArmUCC is not configured.
When having
installed a new ARM
UCC.
When battery jumper
not present and
power fail occurred.
The arm UCC is missing
the following 3 positions.
- Centre box
- In jetters
- Under jetters.
Recalibrate the arm
positions.
80
error
UNDER/OVER
VOLTAGE
Safety device in electro cabinet
giving alarm when excess
voltage is detected.
An error will be
generated, all
activities will be
stopped and Merlin
will go into off-line
modus.
The input activated by
under/over voltage
monitoring unit is
deactivated.
Check mains and reset
alarm.
81
info
STARTUP
Indicate restart of HMI, to notify
in the alarm history list.
Info message will be
generated, milking of
HMI restarted.
No Data