Ref / Pt.No: 294130
Operating Instructions for Safe Use
Fullwood M²erlin
Revision: C
Date: 24-Mar-17
294130
Page 28 of 81
2. In the left window select
M²erlin#1
and select
User Settings
3. At the bottom of the list are the time value settings, click and change the time value, then
click apply. The number of washes can be increased by the engineer.
4. Repeat the steps for the remaining washes.
7.4.2
Backflush
By default a backflush is initiated after every milking, to reduce the risk of cross contamination
from cow to cow. After a cow has been milked, the backflush system sends a jet of water with
compressed air down the liners and to waste via the foremilk rejection chambers.
7.4.3
Cleaning Chemicals
Chemical MUST NOT be stored near M²erlin, as this will cause premature corrosion of the
components.
•
Chemicals should be stored a min. 2m and max. 20m away from the M²erlin.
•
Flexible Chemical tubes should be routed through a solid pipe where ever persons may
be walking underneath. This reduces the risk of harm in the event of a leak.
Chemicals containing CHLORINE or NITRIC ACID
MUST NOT
be used anywhere in the machine as these will cause damage
Only use Fullwood Ltd approved chemicals
.
In addition - use
017439
- Laser Cleaning Solvent for removing lime scale from the laser lens
Teat spray is sprayed automatically after the cow has finished milking via a dosing pump.