Ref / Pt.No: 294130
Operating Instructions for Safe Use
Fullwood M²erlin
Revision: C
Date: 24-Mar-17
294130
Page 16 of 81
•
The filters should be located as close as possible to the compressor but after the air
dryer.
•
If the compressor has no filtration a 0.1 micron filter must be fitted before the drier
and the remaining filters after the drier
2.23 Air Filtration
First stage filter
maximum 0.1 micron to reduce larger particles
Second stage filter maximum 0.01 micron to reduce smaller particles
Carbon filter
to reduce odour and impurities
2.24 Noise
Sound pressure levels have been measured at the above points, 1M from the
surface of the machine and 1.6M from floor level and does not exceed 70 dB(A).
Note; Other surrounding equipment may increase the noise in the working area
subject to their location. This should be assessed when installed.
2.25 Vacuum
•
The vacuum pump shall have adequate airflow capacity to meet the requirements for
milking and cleaning. At a nominal 50kPa the following minimum airflow is required.
Number of M²erlin
Robots
Airflow in litres / minute
One machine
450L/min
Two machines
650L/min
Each additional machine
up to 6
+100L/min
> 6 machines
Contact Fullwood Ltd
These figures are based on installations at sea level (<300m) and will change depending on
altitude
2.26 Water
Pressure
Temperature
Volume
Cold Water Regulated to 1.5 Bar
Ambient
Mains Supply
Hot Water
2m Head minimum*
1.5 Bar Max
92 to 96°C in the boiler
85L**
1
2
3