Ref / Pt.No: 294130
Operating Instructions for Safe Use
Fullwood M²erlin
Revision: C
Date: 24-Mar-17
294130
Page 65 of 81
has been reset by
the user.
19
fatal/error
ARM_
VACUUM
Fatal when arm is turned in,
otherwise Error class.
No Data
Not used by M2.
No Data
20
fatal/error
ARM_WAGON
_POS
Fatal when arm is turned in,
otherwise Error class.
No Data
Not used by M2.
No Data
21
fatal/error
ARM_TEAT
CUP_POS
Fatal when arm is turned in,
otherwise Error class.
Error generated when arm is
having problems turning in.
No Data
Not used by M2.
No Data
22
fatal/error
ARM_NOTEATS
No teats are marked for milking
in data send to Merlin.
Fatal when arm is turned in,
otherwise Error class.
Milking which is
started will be
aborted.
Will happen when main
control software would
start milking a cow with
no teats marked for
milking.
However main control
will not start milking this
cow.
Check laser glass / clean
laser glass / exchange
laser.
23
info
MM_GEN
Not used
Not used
Not used by M2.
Not used
24
info
MM_
COMMUNICATIO
N
Problems in communication to a
milk meter.
In case of a single
message is missed
an info message will
be generated in case
> 5 messages in a
row are missed an
alarm will be
generated.
In case milk meter
communication is failing.
Check milk meter
communication and reset
alarm.