Ref / Pt.No: 294130
Operating Instructions for Safe Use
Fullwood M²erlin
Revision: C
Date: 24-Mar-17
294130
Page 75 of 81
cows will continue as
normal.
82
info
FLASH ERROR
Merlin M2 HMI cannot write to
flash or cannot access flash.
Info message will be
generated, milking of
cows will continue as
normal.
Flash card not
accessible or broken.
Verify (CHKDSK/F) or
exchange flashcard.
83
info
ARM_MILK
SENSOR_LR
Milk sensor gives incorrect value
on LR.
- Air bleed not open? -
Milking will be
terminated; system
will continue milking
other cows.
no increase in milk yield
detected by the milk
meter for 120 seconds
,teat milking for a
minimum of 120
seconds after last
attachment, the total
milk time on that teat is
higher than 140% of the
average milk time on
that teat.
Check arm milk flow
sensor and air bleeds and
reset alarm.
84
info
ARM_MILK
SENSOR_RR
Milk sensor gives incorrect value
on RR.
- Air bleed not open? -
Milking will be
terminated; system
will continue milking
other cows.
no increase in milk yield
detected by the milk
meter for 120 seconds
,teat milking for a
minimum of 120
seconds after last
attachment, the total
milk time on that teat is
higher than 140% of the
average milk time on
that teat.
Check arm milk flow
sensor and air bleeds and
reset alarm.
85
info
ARM_MILK
SENSOR_RF
Milk sensor gives incorrect value
on RF.
- Air bleed not open? -
Milking will be
terminated; system
will continue milking
other cows.
no increase in milk yield
detected by the milk
meter for 120 seconds
,teat milking for a
minimum of 120
seconds after last
attachment, the total
milk time on that teat is
higher than 140% of the
Check arm milk flow
sensor and air bleeds and
reset alarm.