11. Routine Daily Maintenance
Within the milking system there are a number of routine activities that should take place to
ensure the efficient and effective operation of the machine and are as follows;
VACUUM SYSTEM
Check vacuum level
r
Check oil level in vacuum pump
r
CLEANING BRUSHES
Check brushes are working correctly
r
Visual check cleaning of brushes & chemical injection
r
ROBOT ARM
Check teat spray system & chemical level
r
Wash arm & milking equipment with low pressure water
r
Check and clean laser lens
r
Check arm has correct park position
r
Check air bleeds on shells
r
Check the Cartesian belts and rails for damage
r
Check the Z axis rollers are clean and free form dirt
r
MILKING EQUIPMENT
Check teat cups and shells, change if damaged
r
Check condition of ACR ropes
r
Change milk filter minimum twice per day and flush housing with clean water
(Pause the machine if necessary)
r
Check on number of milkings that the liners have done
r
WASHING
Check wash chemical levels
r
Check water temperature during a main clean
r
Check chemical pumps
r
CRATE
Check operation of gates
r
COMPRESSED AIR
Check compressed air pressure
r
Drain receiving vessel
r
Check oil level in pump
r
Check air filters
r
MILKMETER
Check cleanliness of milkmeter body
r
OTHER
Visually check complete system
r
Check any other equipment controlled by the robot
r