Ref / Pt.No: 294130
Operating Instructions for Safe Use
Fullwood M²erlin
Revision: C
Date: 24-Mar-17
294130
Page 67 of 81
than the milking pause timeout
120 minutes).
33
info
SAMPLER_
FRAME_FULL
Last bottle of the sampler has
been filled.
User will get a
warning from the
system.
System waits until
the user arrives or
until the timeout is
passed, the system
will continue milking
other cows.
Last bottle of the
sampler has been filled.
Replace sampler frame
and reset alarm.
34
info
RETRACTABLE
_TEAT
The Retractable teat doesn't
function correctly.
No Data
Not used by M2.
No Data
35
info
CALF_FEEDER
Calf feeder mixer is not filled in
time (by monitoring Mixer Full
signal).
No Data
Not used by M2.
No Data
36
info
D-LINE TIMEOUT
Delivery line is not available for
longer than the set time (45
minutes by default).
Cleaning of milk tank
takes longer than set
time in configurator
and/or milk tank has
jumped in error after
cleaning.
When the delivery-line
to the milk tank is not
available for a longer
time (Than set in the
Configurator).
Check milk tank.
37
info
MILKING
_TIMEOUT
When the milking time of a cow
is longer than two times mean
milk time plus two times mean
dead time, the system will abort
the milking.
Milking will be
terminated; system
will continue milking
other cows.
When the milking time of
a cow is longer than two
times mean milk time
plus two times mean
dead time, the system
will abort the milking.
No Data
38
info
CLEANING
_TIMEOUT
Error will generated if cleaning
time exceeds maximum
Error will be
generated and Merlin
will be set off-line.
Error will generated if
cleaning time exceeds
maximum (Default value
is 30 minutes advanced
engineer setting).
Check the system and
reset alarm.
39
info
SPARE2
No Data
No Data
Not used by M2.
No Data
40
info
MANGER
_SENSOR
The manger pan is not emptied
in time (The value to be entered
No Data
Not used by M2.
No Data