Ref / Pt.No: 294130
Operating Instructions for Safe Use
Fullwood M²erlin
Revision: C
Date: 24-Mar-17
294130
Page 71 of 81
55
info
EAT SENSOR
Alarm raised when eating
sensor is activated at start of a
visit, probably by roughage for
the eating sensor.
Calculations of the roughage
station will probably fail.
No Data
N/A
N/A
56
info
NO COLD
WATER ROLLS
No Data
No Data
N/A
N/A
57
info
END OF
MILKING
No Data
No Data
N/A
N/A
58
warning/error
BLD SENSOR
Error generated if blood sensor
sees 3 animals in a row with
blood in the milk.
Warning when old type blood
sensor doesn't communicate
anymore.
An error will be
generated and Merlin
will go into pause
mode.
No cows will be
milked but cleanings
will be executed.
Error generated if blood
sensor sees 3 animals
in a row with blood in
the milk, warning when
old type blood sensor
doesn't communicate
anymore.
Check the blood sensor.
Sensor needs to be
cleaned or replaced.
59
warning
ABNORMAL
MILK
Only send when animal should
be kept in box when detecting
abnormal milk.
User will get a
warning from the
system.
System waits until
the user arrives or
until the timeout is
passed.
After timeout an error
will be generated, the
cow will be released
and the system will
continue milking
other cows.
Animal is held in box
because of abnormal
milk (blood or
conductivity).
Check and release
animal.
60
warning
BUCKET FULL
All buckets of the bucket system
are filled.
All buckets filled.
HMI reports all buckets
filled.
Empty buckets and
acknowledge in HMI.