Ref / Pt.No: 294130
Operating Instructions for Safe Use
Fullwood M²erlin
Revision: C
Date: 24-Mar-17
294130
Page 73 of 81
will go into off-line
mode.
69
fatal
REJECTION
VALVE
The rejection valve isn't
positioned correctly for milk
pumping/purging.
A fatal error will be
generated and
system will be set in
off-line mode.
The valve feedback is
inverted to the wanted
status of the valve.
Check reject valve and
feedback, reset alarm.
70
error
TANK_VALVE
The tank valve isn't positioned
correctly for milk
pumping/purging.
An error will be
generated and
system will be set in
pause mode.
The valve feedback is
inverted to the wanted
status of the valve.
Check tank valve and
feedback, reset alarm.
71
error
DLINE_VALVE
The Delivery Line valve isn't
positioned correctly for milk
pumping/purging.
An error will be
generated and
system will be set in
pause mode.
The valve feedback is
inverted to the wanted
status of the valve.
Check D-line valve and
feedback, reset alarm.
72
error
FlowVacuum
sensors
One/More of the flow/vacuum
sensors aren’t working.
Broken
pulsator/problem
wiring/pulsator not
programmed and/or
not configured.
System cannot
communicate with
flow/vacuum sensors
and/or flow/vacuum
sensors not present in
FarmCAN network
and/or one of
flow/vacuum sensors
broken.
Verify/correct wiring
/verify/program correct
software version/
verify/redo configuration
in HMI /exchange
corresponding
flow/vacuum sensor.
73
error
PULSATOR
The FarmCan pulsator isn't
working.
Broken flow/vacuum
sensor/problem
wiring, flow, vacuum
sensors not
programmed and/or
not configured.
System cannot
communicate with
pulsator and/or pulsator
not present in FarmCAN
network or pulsator
broken.
Verify/correct wiring
/verify/program correct
software version/
verify/redo configuration
in HMI /exchange
pulsator.
74
error
COW_FOLLOWE
R_NOT_
CONNECTED
The cow follower isn't
communicating.
Wrong or
problematic
connection, wrong IP
address, no power
supply present.
System cannot
communicate with cow
follower.
Verify IP address/assign
new IP address/check
power supply/check
connections/check wiring.