Ref / Pt.No: 294130
Operating Instructions for Safe Use
Fullwood M²erlin
Revision: C
Date: 24-Mar-17
294130
Page 66 of 81
25
info
MM_SENSOR
Milk meter is not seeing Milk
(0.8kg) in Merlin within the milk
meter alarm interval (default 60
sec), while sufficient milk flow is
present.
Since Merlin Facelift
By using value 0 for the interval
this check can be disabled.
As soon as the alarm
is triggered, the
milking will be
terminated and the
Merlin will go into
error mode.
Milk meter is not seeing
Milk (0.8kg) in Merlin
within the milk meter
alarm interval (default
60 sec), while sufficient
milk flow is present.
- Since Merlin Facelift -
By using value 0 for the
interval this check can
be disabled.
Check milk meter and
reset alarm.
26
info
CLEAN_LOW
_TEMP
Not used
Not used
Not used by M2.
Not used
27
info
CHEMICALS
No Data
No Data
Not used by M2.
No Data
28
fatal
MILKPUMP
Merlin cannot finish the milking.
Problems with emptying the milk
reservoir or resetting the milk
meter.
An error will be
generated Merlin will
stop all actions.
Milk vessel is not
emptied within the set
time (default 5 minutes)
after the milk pump has
been started.
Check milk pump and
level sensors and reset
alarm.
29
error/info
MILKING
_ABORTED
Milking aborted by arm control
Box when none of the Failed
Milking End Results are valid.
Milking End Result is first send
as Info, after a number of
failures in a row the alarm is
promoted to Error.
After 3 aborted
milkings in a row an
error will be
generated and the
Merlin will be put in
pause (Cleanings will
be executed).
Milking is aborted by the
'old' arm (Possibly
triggered by the user).
Check system and reset
alarm.
30
info
CONNECTION
_FAILURE
No Data
No Data
No Data
31
info
POWER_
FAILURE
Generated when the Emergency
Stop input is activated
Someone pushed
one or both of the
emergency stop
buttons and/or
problem with wiring.
Emergency stop buttons
input detected.
Unlock emergency stop
button and/or verify wiring
emergency stop buttons.
32
info
MILKING_
PAUSE
In case the system is set in
pause by the delivery line longer
Error will be
generated.
Pause is taking longer
as the set value (Default
Check system and reset
alarm.