ERPA CODES
M2488 PRODUCT GUIDE
C-2
CG00000-011503 REV. A
April 1997
35
Drive Equipment
Check
One of the following has occurred:
1. The control unit cannot recover from a drive-detected error.
2. A check code message is displayed on the drive message display.
3. The automatic cartridge loader does not respond across the interconnection to the
tape drive.
4. A failure occurred during an index/load or unload cycle. The tape cartridge is not
manually retrievable by the operator.
36
End-of-Data
Detected on Read
An End-of-Data (EOD) mark was detected on the tape during a read operation.
37
Tape Length Error
The tape length in the cartridge is too short. The error could occur when the leader
block is replaced (the length of tape ahead of the BOT has been trimmed).
38
Physical End of Tape
A read or write operation was in process when the physical end-of-tape was reached.
The drive does not pull the tape out of the cartridge.
39
Backward at BOT
While the tape was moving backwards, the beginning of tape was reached.
3B
Volume Removed by
Operator
The Rewind Unload switch on the drive has been activated and the cartridge is
unloaded.
41
Block ID Sequence
Error
The control unit detected an incorrect Block ID sequence.
43
Intervention Required
A CDB was issued to a drive that is not ready.
44
Locate Block Unsuc-
cessful
The control unit cannot find the block preceding the desired block.
47
Control Unit Error
The SCSI error processing microcode received an unrecognized ERPA code. Process-
ing continues.
49
Bus Out Parity
The bus out parity error was detected on the command or parameter transfer.
4A
Control Unit ERP
Failed
The control unit could not recover from a data handling failure.
4C
Recovered Hardware
Error
The control unit recovered from a hardware error.
5B
Tape Extension Error
An attempt was made to write 36-Track format data on 18-Track formatted medium.
5C
Medium Changer
Command
A Medium Changer command was given to a device that does not have the Medium
Changer feature.
5D
Tape Length Error
The tape length in the cartridge is too long.
5E
Compaction Algo-
rithm Incompatible
An attempt was made to read an unsupported data compaction algorithm.
6F
No Cartridge
No cartridge at selected location; or selected location not within the magazine size; or
no magazine was present when an attempt was made to load a cartridge from the mag-
azine.
77
Reel Diameter
Greater than ECCST
Reel Diameter Greater than ECCST
Table C-1. ERPA Codes (Continued)
ERPA
CODE
DESCRIPTION
ERROR
Содержание M2488
Страница 1: ...C144 E019 03EN M2488 CARTRIDGE TAPE DRIVE PRODUCT GUIDE ...
Страница 4: ......
Страница 57: ...M2488 PRODUCT GUIDE INSTALLATION INSTRUCTIONS April 1997 CG00000 011503 REV A 1 31 Figure 1 25 Replace Covers ...
Страница 64: ......
Страница 70: ...DESIGN ARCHITECTURE M2488 PRODUCT GUIDE 2 6 CG00000 011503 REV A April 1997 ...
Страница 82: ......
Страница 236: ......
Страница 351: ...M2488 PRODUCT GUIDE MAINTENANCE AND SERVICING April 1997 CG00000 011503 REV A 8 41 Figure 8 2 Interconnect Diagram ...
Страница 359: ...M2488 PRODUCT GUIDE MAINTENANCE AND SERVICING April 1997 CG00000 011503 REV A 8 49 Figure 8 8 DTC PCBA ...
Страница 366: ...MAINTENANCE AND SERVICING M2488 PRODUCT GUIDE 8 56 CG00000 011503 REV A April 1997 ...
Страница 374: ...SENSE KEYS M2488 PRODUCT GUIDE A 2 CG00000 011503 REV A April 1997 ...
Страница 480: ...DIAGNOSTIC TESTS AND ERROR CODES M2488 PRODUCT GUIDE F 80 CG00000 011503 REV A April 1997 ...
Страница 522: ...INDEX M2488 PRODUCT GUIDE Index 8 CG00000 011503 REV A April 1997 ...
Страница 524: ......
Страница 525: ...M2488 CARTRIDGE TAPE DRIVE PRODUCT GUIDE C144 E019 03EN M2488 CARTRIDGE TAPE DRIVE PRODUCT GUIDE C144 E019 03EN ...
Страница 526: ......
Страница 527: ......
Страница 528: ......