MTU DIAGNOSTIC SPECIFICATIONS
M2488 PRODUCT GUIDE
H-6
CG00000-011503 REV. A
April 1997
H-4.3.3
ACL TEST: Two diagnostic tests to check the autoloader
(Set the tests in detail using the given parameters.)
The tests can be set using the following parameters:
H-4.3.4
TESTMODE: Diagnostic test to measure operations
(This test has no parameter.)
0x00 - S:LD HM
: Start loading from the loader home position.
0x01 - S:CTG IN
: Start loading from the cartridge-in position.
0x02 -
S:CAR DW
: Start loading from the carrier-down position.
DIAG parameter 4: For WITH CTG only, select an unloading position from the following:
0x00 - E:TH END
: Start unloading from the thread end.
0x01 - E:CAR DW
: Start unloading from the carrier-down position.
0x02 - 1/6 F PT
: Start unloading from the cartridge-in position.
execute count: Specify an execution count. Specify a command execution count from 1 to 99,999.
When 0 is set, the command execution continues with no stop.
1)
ACL LDUL
:
Load and unload cartridges sequentially from the top posi-
tion of the magazine.
------- CMD CD : 0x
90
2)
MAG UPDW
:
Move the magazine between two position.
------- CMD CD : 0x
91
DIAG parameter 3: For MAGAZINE UP/DOWN test, set the following:
0xXX- STRT Position
: Magazine up-down start position
ACL type:
0x00 - 0x09 (10 slot type)
0x00 - 0x04 (5 slot type)
FACL type:
0x00 - 0x06
DIAG parameter 4: For MAGAZINE UP/DOWN test, set the following:
0xXX- END Position
: Magazine up-down end position.
ACL type:
0x00 - 0x09 (10 slot type)
0x00 - 0x04 (5 slot type)
FACL type:
0x00 - 0x06
execution time: For ACL LOAD/UNLOAD test, set the frequency in use of cleaning cartridge. Cleaning
cartridge in cleaning cell is loaded every setting counter. (from 1 to 99,999) Only FACL.
If DIAG command code is set “0x90” and execution time is set “999”, cleaning cartridge
is loaded one time.
execute count: Specify an execution count. Specify a command execution count from 1 to 99,999.
When 0 is set, the command execution continues with no stop.
1)
M1:LOAD
:
Measure the cartridge loading time
------- CMD CD : 0x41
2)
M2:TPPFM
:
Measure the tape acceleration/deceleration time.
------- CMD CD : 0x
42
3)
M3:AC/PS:
Measure the tape access/positioning time.
------- CMD CD : 0x43
4)
M4:MODCH: Measure the mode change time.
------- CMD CD : 0x44
5)
M5:LOCAT:
Measure the tape locating time.
------- CMD CD : 0x45
6)
M6:REWND:
Measure the tape rewinding time.
------- CMD CD : 0x46
7)
M7:D.S.E:
Measure the DSE time.
------- CMD CD : 0x47
8)
M8:UNLD:
Measure the cartridge unloading time.
------- CMD CD : 0x48
9)
M9:CLEAN:
Measure the cleaning time.
------- CMD CD : 0x49
Содержание M2488
Страница 1: ...C144 E019 03EN M2488 CARTRIDGE TAPE DRIVE PRODUCT GUIDE ...
Страница 4: ......
Страница 57: ...M2488 PRODUCT GUIDE INSTALLATION INSTRUCTIONS April 1997 CG00000 011503 REV A 1 31 Figure 1 25 Replace Covers ...
Страница 64: ......
Страница 70: ...DESIGN ARCHITECTURE M2488 PRODUCT GUIDE 2 6 CG00000 011503 REV A April 1997 ...
Страница 82: ......
Страница 236: ......
Страница 351: ...M2488 PRODUCT GUIDE MAINTENANCE AND SERVICING April 1997 CG00000 011503 REV A 8 41 Figure 8 2 Interconnect Diagram ...
Страница 359: ...M2488 PRODUCT GUIDE MAINTENANCE AND SERVICING April 1997 CG00000 011503 REV A 8 49 Figure 8 8 DTC PCBA ...
Страница 366: ...MAINTENANCE AND SERVICING M2488 PRODUCT GUIDE 8 56 CG00000 011503 REV A April 1997 ...
Страница 374: ...SENSE KEYS M2488 PRODUCT GUIDE A 2 CG00000 011503 REV A April 1997 ...
Страница 480: ...DIAGNOSTIC TESTS AND ERROR CODES M2488 PRODUCT GUIDE F 80 CG00000 011503 REV A April 1997 ...
Страница 522: ...INDEX M2488 PRODUCT GUIDE Index 8 CG00000 011503 REV A April 1997 ...
Страница 524: ......
Страница 525: ...M2488 CARTRIDGE TAPE DRIVE PRODUCT GUIDE C144 E019 03EN M2488 CARTRIDGE TAPE DRIVE PRODUCT GUIDE C144 E019 03EN ...
Страница 526: ......
Страница 527: ......
Страница 528: ......