M2488 PRODUCT GUIDE
MTU DIAGNOSTIC SPECIFICATIONS
April 1997
CG00000-011503 REV. A
H-5
The tests can be set using the following parameters:
H-4.3.2
LOAD/UNLOAD: Two diagnostic tests to check loading and unloading
(Set the tests in detail using the given parameters.)
The tests can be set using the following parameters:
DIAG parameter 1: For “FRD READ”, “BWD READ” or “WRITE”, set the operation mode.
0x00 - STREAMING
: Set a continuous read (or write) operation.
0x01 - START/STOP
: Set the start/stop operation.
: For “LOCATE”, specify a sector. Specify a location sector from 1 to 99.
DIAG parameter 2: For “FWD READ”, “BWD READ”, “WRITE”, “FRD/BRD”, “L.W.R.” and “FEED
THR”, specify a test wrap.
0x00 - WRAP 1
: Wrap-1 test
0x01 - WRAP 2
: Wrap-2 test
DIAG parameter 4: For “WRITE”, select a write data pattern from the following:
0x00 - D.S.E. PT
: D.S.E. pattern
0x01 - 2 F PT
: 2F pattern
0x02 - 1/6 F PT
: 1/6F pattern
0x03 - 1/5 F PT
: 1/5F pattern
0x04 - 1/4 F PT
: 1/4F pattern
0x05 - 1/3 F PT
: 1/3F pattern
0x06 - 1/2 F PT
: 1/2F pattern
0x07 - 1 F PT
: 1F pattern
0x08 - 1/12 F PT
: 1/12F pattern
0x09 - 1.5 F PT
: 1.5F pattern
DIAG parameter 5: For “L.W.R.”, select a path of the Loop Write To Read command from the following:
0x00 - PATH:A
: Path A
0x01 - PATH:B
: Path B
DIAG parameter 6: For “L.W.R.”, set a level of the Loop Write To Read command from the following:
0x00 - LEVEL LO
: Low level
0x01 - LEVEL HI
: High level
execution time: When diag parameter 1 is START/STOP, set the GO ON time (time when the tape is
running).1 count is 10msec.
If this parameter is set to “0,” the GO ON time becomes 10 ms.
: For the path test, specifies start position by the machine reel counter.
stop time: When diag parameter 1 is START/STOP, set the GO OFF time (time when the tape is
not running). 1 count is 10msec.
If this parameter is set to “0,” the GO OFF time becomes 0 ms.
: For the path test, specifies end position by the machine reel counter.
execute count: Specify an execution count. Specify a command execution count from 1 to 99,999.
When 0 is set, the command execution continues with no stop.
1)
NO CTG
:
Loader and Threader test not using cartridge
------- CMD CD : 0x
20
2)
WITH CTG
:
Loader and Threader test using cartridge.
------- CMD CD : 0x
21
DIAG parameter 2: For NO CTG, select a test type from the following:
0x00 - LOADER
: Loader test
0x01 - THREADER
: Threader test.
DIAG parameter 3: For WITH CTG, select a loading position from the following:
Содержание M2488
Страница 1: ...C144 E019 03EN M2488 CARTRIDGE TAPE DRIVE PRODUCT GUIDE ...
Страница 4: ......
Страница 57: ...M2488 PRODUCT GUIDE INSTALLATION INSTRUCTIONS April 1997 CG00000 011503 REV A 1 31 Figure 1 25 Replace Covers ...
Страница 64: ......
Страница 70: ...DESIGN ARCHITECTURE M2488 PRODUCT GUIDE 2 6 CG00000 011503 REV A April 1997 ...
Страница 82: ......
Страница 236: ......
Страница 351: ...M2488 PRODUCT GUIDE MAINTENANCE AND SERVICING April 1997 CG00000 011503 REV A 8 41 Figure 8 2 Interconnect Diagram ...
Страница 359: ...M2488 PRODUCT GUIDE MAINTENANCE AND SERVICING April 1997 CG00000 011503 REV A 8 49 Figure 8 8 DTC PCBA ...
Страница 366: ...MAINTENANCE AND SERVICING M2488 PRODUCT GUIDE 8 56 CG00000 011503 REV A April 1997 ...
Страница 374: ...SENSE KEYS M2488 PRODUCT GUIDE A 2 CG00000 011503 REV A April 1997 ...
Страница 480: ...DIAGNOSTIC TESTS AND ERROR CODES M2488 PRODUCT GUIDE F 80 CG00000 011503 REV A April 1997 ...
Страница 522: ...INDEX M2488 PRODUCT GUIDE Index 8 CG00000 011503 REV A April 1997 ...
Страница 524: ......
Страница 525: ...M2488 CARTRIDGE TAPE DRIVE PRODUCT GUIDE C144 E019 03EN M2488 CARTRIDGE TAPE DRIVE PRODUCT GUIDE C144 E019 03EN ...
Страница 526: ......
Страница 527: ......
Страница 528: ......