TAPE UNIT SCSI COMMANDS
M2488 PRODUCT GUIDE
4-128
CG00000-011503 REV. A
April 1997
Description of Page Code 80h
This page allows user selection of Online Diagnostic Routines and control over the number of
times each routine is to be executed.
Selection of a diagnostic routine is accomplished by assigning a routine’s corresponding Execute
Count byte a non-zero value. Routines 50 to 57 are diagnostic specific to the Tape Drive logical
unit, and routines C0 and C2 are specific to the Medium Changer logical unit. Therefore, if the
Tape Drive logical unit is selected, only the Execute Count bytes corresponding to the Selftest rou-
tine (Routine 01) and routines 50 to 57 may have non-zero values. Bytes 1, 10-11, and 13-19 must
be zero; otherwise a CHECK CONDITION is returned with Sense Key set to ILLEGAL
REQUEST and Additional Sense Key set to INVALID FIELD IN PARAMETER LIST. Con-
versely, if the Medium Changer logical unit has been selected, only the Execute Count bytes corre-
sponding to routine C0 and/or C2 may have non-zero values. Bytes 1, 4-12, and 15-19 must be
zero; otherwise a CHECK CONDITION is returned with Sense Key set to ILLEGAL REQUEST
and Additional Sense Key set to INVALID FIELD IN PARAMETER LIST.
Selection of routines 50 and 51 do not require either DevOfl or UnitOfl to be set. Selection of rou-
tines 52 to 57, or C0 to C2 require both DevOfl and UnitOfl to be set. If a parameter list is received
by the controller which indicates selection of any of the routines 52 to 57, or C0 and/or C2, and
both UnitOfl and DevOfl are not set, a CHECK CONDITION is returned with Sense Key set to
ILLEGAL REQUEST and Additional Sense Key is set to INVALID FIELD IN PARAMETER
LIST.
If any error condition is encountered during execution of a routine, diagnostic result data is gener-
ated at that time and no further diagnostic execution occurs.
Table 4-119. Page 80h - Online Diagnostic Test Page
BITS
BYTES
7
6
5
4
3
2
1
0
0
Page code (80h)
1
Reserved (All bits are set to zero)
2-3
Page Length (0010h)
4
Execute Count (Pass Count) of Online Routine 01h (Self Test)
5
Execute Count (Pass Count) of Online Routine 50h
6
Execute Count (Pass Count) of Online Routine 51h
7
Execute Count (Pass Count) of Online Routine 52h
8
Execute Count (Pass Count) of Online Routine 53h
9
Execute Count (Pass Count) of Online Routine 54h
10-11
Reserved (All bits are set to zero)
12
Execute Count (Pass Count) of Online Routine 57h
13
Execute Count (Pass Count) of Online Routine C0h
14
Execute Count (Pass Count) of Online Routine C2h
15-19
Reserved (All bits are set to zero)
Содержание M2488
Страница 1: ...C144 E019 03EN M2488 CARTRIDGE TAPE DRIVE PRODUCT GUIDE ...
Страница 4: ......
Страница 57: ...M2488 PRODUCT GUIDE INSTALLATION INSTRUCTIONS April 1997 CG00000 011503 REV A 1 31 Figure 1 25 Replace Covers ...
Страница 64: ......
Страница 70: ...DESIGN ARCHITECTURE M2488 PRODUCT GUIDE 2 6 CG00000 011503 REV A April 1997 ...
Страница 82: ......
Страница 236: ......
Страница 351: ...M2488 PRODUCT GUIDE MAINTENANCE AND SERVICING April 1997 CG00000 011503 REV A 8 41 Figure 8 2 Interconnect Diagram ...
Страница 359: ...M2488 PRODUCT GUIDE MAINTENANCE AND SERVICING April 1997 CG00000 011503 REV A 8 49 Figure 8 8 DTC PCBA ...
Страница 366: ...MAINTENANCE AND SERVICING M2488 PRODUCT GUIDE 8 56 CG00000 011503 REV A April 1997 ...
Страница 374: ...SENSE KEYS M2488 PRODUCT GUIDE A 2 CG00000 011503 REV A April 1997 ...
Страница 480: ...DIAGNOSTIC TESTS AND ERROR CODES M2488 PRODUCT GUIDE F 80 CG00000 011503 REV A April 1997 ...
Страница 522: ...INDEX M2488 PRODUCT GUIDE Index 8 CG00000 011503 REV A April 1997 ...
Страница 524: ......
Страница 525: ...M2488 CARTRIDGE TAPE DRIVE PRODUCT GUIDE C144 E019 03EN M2488 CARTRIDGE TAPE DRIVE PRODUCT GUIDE C144 E019 03EN ...
Страница 526: ......
Страница 527: ......
Страница 528: ......