MAINTENANCE AND SERVICING
M2488 PRODUCT GUIDE
8-20
CG00000-011503 REV. A
April 1997
8-4.3.2
Off-Line Diagnostic Menu through the Remote Maintenance (RS-232) Interface
Off-Line diagnostic tests may be invoked and run through the RS-232 interface as well as the
Operator Control Panel interface. Diagnostic tests are selected and executed in the same manner
regardless of which interface is used, however the RS-232 interface is easier to use, more flexible,
and provides more detailed error information.
The RS-232 user interface is a command-set driven architecture. A basic set of commands is pro-
vided to facilitate the selection and execution of diagnostic tests. The Diagnostic Microcode archi-
tecture is a list processing architecture. The RS-232 user interface command set enables the
creation, modification, and deletion of tests to build a test list. The command set also includes the
capability to begin test execution, provide user help information, and exit the Off-Line diagnostic
mode. Multiple commands may be entered on the same line using a semicolon “;” as a separator.
The usual sequence of operations would be to first create a list of tests to be executed. Then, mod-
ify any test options as desired. Finally, begin test execution. A description of the commands to
accomplish these steps are outlined in section .
*Add
A: ####
Add a test to the end of the test list. The following example shows how to add
Routine 0x09, Test 0x02:
Example: A: 0902
Options
STOP ERR
CONT ERR
Select STOP ERR for stop on error or CONT ERR for continue on error.
*Delete
D: ####
Delete the test at node number n in the current test list. The following example
shows how to delete node 8 through the end of the current test list:
Example: D: 0800
*List
L: ####
List the tests in the current test list. The following example shows how to list
nodes 5 through 10 of the current test list:
Example: L: 050A
* This command is available only if FACTORY MODE is enabled.
Table 8-17. Operator Panel Off-Line Diagnostics (Continued)
COMMAND
SELECTION
OR RESPONSE
DESCRIPTION
A
:
0
9
0
2
“Add”
Routine Number
Test Number
D
:
0
8
0
0
“Delete”
Beginning node
Ending node
L
:
0
5
0
A
“List”
Beginning node
Ending node
Содержание M2488
Страница 1: ...C144 E019 03EN M2488 CARTRIDGE TAPE DRIVE PRODUCT GUIDE ...
Страница 4: ......
Страница 57: ...M2488 PRODUCT GUIDE INSTALLATION INSTRUCTIONS April 1997 CG00000 011503 REV A 1 31 Figure 1 25 Replace Covers ...
Страница 64: ......
Страница 70: ...DESIGN ARCHITECTURE M2488 PRODUCT GUIDE 2 6 CG00000 011503 REV A April 1997 ...
Страница 82: ......
Страница 236: ......
Страница 351: ...M2488 PRODUCT GUIDE MAINTENANCE AND SERVICING April 1997 CG00000 011503 REV A 8 41 Figure 8 2 Interconnect Diagram ...
Страница 359: ...M2488 PRODUCT GUIDE MAINTENANCE AND SERVICING April 1997 CG00000 011503 REV A 8 49 Figure 8 8 DTC PCBA ...
Страница 366: ...MAINTENANCE AND SERVICING M2488 PRODUCT GUIDE 8 56 CG00000 011503 REV A April 1997 ...
Страница 374: ...SENSE KEYS M2488 PRODUCT GUIDE A 2 CG00000 011503 REV A April 1997 ...
Страница 480: ...DIAGNOSTIC TESTS AND ERROR CODES M2488 PRODUCT GUIDE F 80 CG00000 011503 REV A April 1997 ...
Страница 522: ...INDEX M2488 PRODUCT GUIDE Index 8 CG00000 011503 REV A April 1997 ...
Страница 524: ......
Страница 525: ...M2488 CARTRIDGE TAPE DRIVE PRODUCT GUIDE C144 E019 03EN M2488 CARTRIDGE TAPE DRIVE PRODUCT GUIDE C144 E019 03EN ...
Страница 526: ......
Страница 527: ......
Страница 528: ......