4.5.21 Installing the underpressure controller
❒ Assemble the double thread nipple (1), reduction union (2) and hose nipple (3).
❒ Screw this assembly into the right of the stoker.
❒ Fix the underpressure sensor (4) with two self-tapping screws to the insulation
side panel.
❒ Insert the hose clamp (5) on the silicon hose and on the hose nipple (3) and then
tighten.
❒ Fit the spring washer (6).
❒ Fix the other end of the silicon hose to the "-" nipple of the underpressure sensor
(4) with the hose clamp (5) and tighten.
➥ Do not remove the red reduction plug.
4.5.22 Installing the automatic ignition
❒ Screw in the igniter tube (1).
❒ Insert the double wire hose clip (2) on the igniter tube (1).
❒ Insert the ignition blower (3) into the igniter tube (1) and fix in place using the dou‐
ble wire hose clip (2).
❒ Fit the cover.