![Froling TURBOMAT TM 150 Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/froling/turbomat-tm-150/turbomat-tm-150_installation-instructions-manual_2338754030.webp)
4.5.9 Fitting the heat exchanger ash removal unit with ash screw (optional)
Heat exchanger right
Heat exchanger left
The following instructions are for fitting the automatic heat exchanger ash removal
screw unit to a boiler with the heat exchanger mounted on the right. The instructions
also apply to boilers with the heat exchanger mounted on the left. It is important to
note that the gear motor (1) must always be mounted on the combustion chamber
side. This is to ensure that in the event of a roller chain fault ash removal will take
place at the first pull. With the heat exchanger on the right, the chain tensioner (2) is at
the bottom. With the heat exchanger on the left, the chain tensioner is at the top.
❒ Grease the shaft stub on both ash screws.
❒ Fit the gear motor (1) complete with the seal gasket (2) to the flange plate (3).
❒ Insert the ash screw (4) through the flange plate and into the gear motor.
➥ The key groove in the ash screw must be aligned with the key groove in the
gear motor.
❒ Slide the motor key (5) into the groove.
❒ Fit the sprocket (6).
❒ Slide the sprocket key (7) into the groove and fit the shaft retainer (8).
4
Installation
Installing the boiler
30
Fröling GesmbH | A-4710 Grieskirchen, Industriestraße 12 | www.froeling.com