![Froling TURBOMAT TM 150 Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/froling/turbomat-tm-150/turbomat-tm-150_installation-instructions-manual_2338754023.webp)
❒ Refit the front cover (1) and the back cover (2) to the heat exchanger.
❒ Fit the blanking cover to the air duct channel on the front of the heat exchanger.
4.5.5 Changing over the WOS rods (where necessary)
The WOS drive is always fitted to the back of the boiler opposite the control cabinet. If
the heat exchanger is installed on the left it will be necessary to change over the WOS
rods as follows.
❒ Lock the lock nuts (1) on the knobs (2). Turn the knobs (2) clockwise until they
stop and then open the heat exchanger cover.
❒ Lock the clamping pad (3) on the WOS lever (4) and pull it out of the WOS shaft
(5).
❒ Remove the clamping bracket (6) and fit it on the opposite side.
Installation
4
Installing the boiler
Installation Instructions | M0650314_en
23