4.5.14 Fitting the door contact switch
❒ Attach the cover plate (1) to the combustion chamber door and fix it in place on
the left and right with self-tapping screws.
❒ Fit the door contact switch (2) to the frame element.
❒ Set the door contact switch as follows:
➥ Loosen the screws (1) on the key plate (2).
➥ Close the combustion chamber door and as you are doing this slide the key
plate (2) so that it engages smoothly with the door contact switch (3).
➥ Fix the key plate in position (2). Open and close the combustion chamber door
several times and check that the door contact switch (3) is tripped correctly.
➥ Lay the connecting cable through the opening in the frame element and then
onwards to the control cabinet.
❒ Fit the side cable duct (4).
❒ Fit the cover (5).