![Froling TURBOMAT TM 150 Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/froling/turbomat-tm-150/turbomat-tm-150_installation-instructions-manual_2338754031.webp)
❒ Fit the bearing bracket (1) to the flange plate (2).
❒ Insert the ash screw (3) through the flange plate.
❒ Fit the sprocket (4).
❒ Slide the key (5) into the groove and fit the shaft retainer (6).
❒ Push the flange plates with the ash screw into the back of the boiler as shown in
the figure. Fix to the insulation side panel with screws.
❒ Fit the chain tensioner (1) to the bearing block.
➥ Engage the chain tensioner (1) with the bolts on the bearing block so that the
chain is tensioned correctly.
❒ Set the sprocket on the chain tensioner so that all the three sprockets are aligned
with each other.
❒ Wind the roller chain onto the motor and bearing bracket sprockets. Tension the
chain and fix in place with the spacer sleeve.
Installation
4
Installing the boiler
Installation Instructions | M0650314_en
31