Foundry NetIron MLX Series Installation and Basic Configuration Guide
8-2
© 2008 Foundry Networks, Inc.
December 2008
Table 8.1, Table 8.2 and Table 8.3 provide the maximum power calculations for the NetIron MLX Series chassis.
.
.
Table 8.4 lists the maximum power consumption, in watts, for NetIron MLX Series modules.
Table 8.1: Maximum Power Calculations at 100 VAC
NetIron MLX Series Chassis
Amps
Watts
BTUs Per Hour
NetIron MLX-4
13
1313
4480
NetIron MLX-8
26
2607
8899
NetIron MLX-16
53
5286
18041
NetIron MLX-32
N/A
N/A
N/A
Table 8.2: Maximum Power Calculations at 200 VAC
NetIron MLX Series Chassis
Amps
Watts
BTUs Per Hour
NetIron MLX-4
7
1313
4480
NetIron MLX-8
13
2607
8899
NetIron MLX-16
26
5286
18041
NetIron MLX-32
54
10781
36797
Table 8.3: Maximum Power Calculations at 48 VDC
NetIron MLX Series Chassis
Amps
Watts
BTUs Per Hour
NetIron MLX-4
27
1313
4480
NetIron MLX-8
54
2607
8899
NetIron MLX-16
110
5286
18041
NetIron MLX-32
225
10781
36797
Table 8.4: Wattage Consumed by Individual Components
Module
Maximum Power
Consumption, in Watts
Management (NetIron MLX-4, NetIron
MLX-8 and NetIron MLX-16)
30W
Management (NetIron MLX-32)
35W
Switch Fabric
NI-X-SF1 4-slot switch fabric module
(NetIron MLX-4, NetIron MLX-8 and
NetIron MLX-16)
19W