Foundry NetIron MLX Series Installation and Basic Configuration Guide
5-4
© 2008 Foundry Networks, Inc.
December 2008
Displaying the Syslog Configuration and Static and Dynamic Buffers
For information about configuring Syslog, see the
Foundry Switch and Router Installation and Basic Configuration
Guide
.
Slot <num>
Slot1 – Slot16
NetIron MLX-4: Slot1 – Slot4
NetIron MLX-8: Slot1 – Slot8
NetIron MLX-16: Slot1 – Slot16
NetIron MLX-32: Slot1 – Slot32
The slot <num> is the slot number as positioned in the chassis.
The priority of each chassis slot as configured by the
lp-slot-priority
command. The priority can be 1 – 8, where 1 is the lowest priority and 8 is
the highest priority (the default priority is 1). If the supply of power to the
chassis falls below a minimum threshold, the chassis slots with the lowest
priority will likely lose power. For information about using the
lp-slot-
priority
command, see “Changing Priority of Chassis Slots for Interface
Fans
Fan <number>
Information about fans in the NetIron MLX Series chassis.
Status
The status of a fan can be one of the following:
•
OK – The fan is functioning properly and is keeping the temperature
of each module within an acceptable temperature range.
•
Failed – The fan is not functioning properly or the fan control module
cannot control the fan.
Speed
The speed of a fan can be one of the following:
•
Low – The fan is functioning at 50 percent of capacity.
•
Medium – The fan is functioning at 75 percent of capacity.
•
Medium-high – The fan is functioning at 90 percent of capacity.
•
High – The fan is functioning at 100 percent of capacity.
Temperature Readings
Active and Standby Mgmt Module
The temperature of the active and standby management modules.
Fan <number>
The temperature of fan0 and fan1.
SNM<number>
The temperature of the switch fabric module.
LP<number>
The temperature of the interface module.
Temperature Monitoring Poll Period
The interval at which the system reads the temperature sensor on the
management, switch fabric, interface, and fan control modules.
Misc Info
Backplane EEPROM MAC Address
The MAC address of the NetIron MLX chassis.
Table 5.1: Chassis Status and Temperature Information (Continued)
This Field...
Displays...