![Foundry Networks NetIron MLX-16 Скачать руководство пользователя страница 141](http://html1.mh-extra.com/html/foundry-networks/netiron-mlx-16/netiron-mlx-16_installation-and-configuration-manual_2324265141.webp)
Maintaining a NetIron MLX Series Router
December 2008
© 2008 Foundry Networks, Inc.
6-11
The <decimal> variable specifies the number of flaps within an hour after which a power supply will automatically
shutdown. The threshold range is 0 to 32. A value of 0 disables the power supply auto-shutdown on flapping.
NOTE:
A threshold value of 0 will not automatically shutdown a power supply due to failures.
For Syslog messages, please refer to the Foundry NetIron Series Configuration Guide, Appendix A (Using
Syslog), Table A.3 Foundry Syslog Messages: System.
Clearing Power Supply Failure Timestamps
The
power-supply monitoring clear
command is used to clear all collected failure timestamps for a given power
supply, or for all available power supplies.
To clear all collected failure timestamps for a power supply, enter the following command:
NetIron#(config)power-supply monitoring clear 1
This will clear all collected failure timestamps for the Power Supply # 1
Are you sure? (enter 'y' or 'n'): y
To clear all collected failure timestamps for all available power supplies, enter the following command:
NetIron#(config)power-supply monitoring clear all
This will clear all collected failure timestamps for all available Power Supplies
Are you sure? (enter 'y' or 'n'): y
You are asked to verify this command by entering “yes” or “no.
Syntax:
power-supply monitoring clear <decimal | all>]
By default, no power-supply monitoring is configured.
The <decimal> variable specifies a power supply number. The <all> variable clears all available power supplies.
Displaying Power Supply Monitoring Timestamps
To display timestamps for failures on any given power supply, enter the following command:
NetIron#show power-supply-monitoring
The
show power-supply-monitoring
command displays the last 32 recorded failure timestamps for a power
supply. The current configured power supply monitoring threshold value is also displayed at the end of the output.
Syntax:
show power-supply-monitoring
Enabling a Power Supply Shutdown
The
power-off power-supply
command allows you to shutdown a power supply manually.
NetIron#show power-supply-monitoring
PS-1 PS-2 PS-3 PS-4 PS-5 PS-6 PS-7 PS-8
1 ) 0 0 0 0 0 0 0 0
2 ) 0 0 0 0 0 0 0 0
3 ) 0 0 0 0 0 0 0 0
4 ) 0 0 0 0 0 0 0 0
5 ) 0 0 0 0 0 0 0 0
6 ) 0 0 0 0 0 0 0 0
7 ) 0 0 0 0 0 0 0 0
8 ) 0 0 0 0 0 0 0 0
9 ) 0 0 0 0 0 0 0 0