Managing the NetIron MLX Series Chassis and Modules
December 2008
© 2008 Foundry Networks, Inc.
5-3
The display shows the following information:
Table 5.1: Chassis Status and Temperature Information
This Field...
Displays...
Powers
Power <num>, <part num>
The <num> is the power supply number as positioned in the chassis. The
number of power supplies are as follows:
NetIron MLX 4000: 1 – 3
NetIron MLX 8000: 1 – 4
NetIron MLX 16000: 1 – 8
NetIron MLX 32000: 1 – 8
The <part num> is the part number of the power supply purchased. This
applies to AC and DC power supplies.
Power <status>
Indicates whether an AC power supply is installed in the specified power
supply slot and the status of the power supply, which can be one of the
following:
•
Installed (Shutdown)-The power supply is shutdown. A power supply
will shutdown due to flapping, or if a shutdown is enabled manually
using the
power-off power-supply
command. See “Enabling a
Power Supply Shutdown” on page 6-11.
•
Installed (OK) – The power supply is functioning properly and
supplying power to the chassis and installed modules.
•
Failed – The power supply is not functioning and is not supplying
power to the chassis and installed modules.
•
not present – There is no power supply installed in the slot.
•
Installed (Failed or Disconnected) - The power supply is not
functioning, or the power supply is not connected to the chassis and
installed modules.
Total power budget for chassis
The sum of all power (in watts), used by each of the power supplies
currently functioning in the chassis. See “ Wattage Consumed by
Individual Components” on page 8-2.
Total power used by system core
The total power consumption used by the Management modules, switch
fabric modules, and fans. Each chassis type consumes different amounts
of power.
Total power used by LPs
The total power consumption used by the interface module. Each module
type consumes different amounts of power.
Total power available
The total power budget for the chassis minus the total power used by the
system core and the interface modules currently installed.
Slot Power-On Priority
The configured power-on priority of each interface module installed in a
chassis slot.