15 Data transmission
FLUXUS F401
15.5 Data structure
97
UMFLUXUS_F401V2-1EN, 2020-06-12
Next, the line
\DATA
is transmitted. Followed by the column titles, see Tab. 15.2, for the
corresponding channel. The measured values are transmitted afterwards.
Depending on the storage interval, one data line per activated measuring channel is
transmitted. The line "
???
" will be transmitted if there are no measured values available
for the storage interval.
Example
\DEVICE
\MODE
DATE
TIME
Par.Record
Meas.Point No.:
Pipe
Outer Diameter
Wall Thickness
Roughness
Pipe Material
Lining
Medium
Medium Temperat.
Fluid pressure
Transducer Type
Sound Path
Transd. Distance
Damping
Full-Scale Val.
Physic. Quant.
Unit Of Measure
Numb.Of Meas.Val
: F401 -XXXXXXXX
: ONLINE
: 2018-01-09
: 19:56:52
: A:F5050
: 60.3 mm
: 5.5 mm
: 0.1 mm
: Carbon Steel
: WITHOUT LINING
: Water
: 38 C
: 1.00 bar
: xxx
: 3 NUM
: -15.6 mm
: 20 s
: 4.50 m3/h
: Volume flow
: [m3/h]/[m3]
: 100
Example
\DATA
A: \*MEASURE; Q_POS; Q_NEG;
B: \*MEASURE; Q_POS; Q_NEG;