16 Advanced functions
16.3 Totalizers
FLUXUS F401
2020-06-12, UMFLUXUS_F401V2-1EN
104
Stop of the measurement
• Press key I/O.
The following display appears:
• Press key BRK to deactivate the night-flow mode.
If no key is pressed, the transmitter changes over to the resting phase after completing
30 s.
16.3
Totalizers
The total volume or total mass of the fluid at the measuring point can be determined.
There are 2 totalizers, one for the positive and the other for the negative flow direction.
The unit of measurement used for totalizing corresponds to the volume or mass unit se
-
lected for the physical quantity.
The totalizer values can be displayed with up to 11 places, e.g.,
74890046.03
. For the
adjustment of the decimal places (max. 4), see section 17.8.
Display of the totalizer
• Press key
during the measurement to scroll through the upper line and display the
totalizers.
Notice!
While the low-power mode is activated, the totalizers are deactivated.
Notice!
If the night-flow mode is activated, the totalizers are set to zero when starting a mea
-
surement.
>Goodbye in 30 s
...
m3/h
Volume flow
54.5
m3/h
32.5
m3
54.5
m3/h