2 Safety instructions
FLUXUS F401
2.1 General safety instructions
9
UMFLUXUS_F401V2-1EN, 2020-06-12
2
Safety instructions
2.1
General safety instructions
Prior to any work, read the operating instruction carefully and in full.
Failure to comply with the instructions, in particular with the safety instructions, poses a
risk to health and can lead to material damages. For further information, contact FLEXIM.
During installation and operation of the measuring equipment, observe the ambient and
installation conditions specified in the documentation.
The measuring equipment has to be checked for proper condition and operational safety
before each use. If troubles or damages have occurred during installation or operation of
the measuring equipment, please inform FLEXIM.
It is not allowed to make unauthorized modifications or alterations to the measuring equip
-
ment.
The personnel has to be suitably trained and experienced for the work.
2.2
Intended use
The measuring equipment is intended for the measurement of fluid properties in closed
pipes. By means of connected transducers, the transit times of the ultrasonic signals in
the fluid and the pipe are measured and evaluated.
The transmitter uses these values to calculate the sought quantities, e.g., volumetric flow
rate, mass flow rate, heat quantity, density and concentration. Through comparison with
the values stored in the transmitter further physical quantities can be determined. The
physical quantities are provided via configurable outputs and the display.
• All instructions of this operating instruction have to be observed to ensure intended use.
• Any use beyond or other than the intended use is not covered by warranty and can
present a danger. Any damage arising from not intended use shall be solely the liability
of the operator or user.
• The measurement is carried out without direct contact to the fluid in the pipe. The flow
profile is not influenced.
• The transducers are fixed to the pipe using the supplied transducer mounting fixture.
• Observe the operating conditions, e.g., environment, voltage ranges. For the technical
data of the transmitter, transducers and accessories, see technical specification.