Chapter 8 System Operation
PAGE 8- 10
8-3-3 Fastening Result Display Mode
The following data is displayed in Fastening Result Mode. In the fastening result mode, “r.” is indicated at
the 100s digit of the PAR No. indication part and the parameter No. (01 to 32) of the fastening operation that
was performed is indicated by the 10s and 1s digits. By pressing the [
▲
] or [
▼
] push-button, the “D-NO”
can be changed ±1. The numbers can be advanced 5 at a time by holding the [
▲
] or [
▼
] push-button longer.
*If fastening has not been started, “r.00” is displayed.
PAR No. D-No.
DATA
Unit
r.01~32
000
Peak Torque H/L
Nm
001
Final Angle H/L
deg
002
Rate 1 H/L
Nm/deg
003
Rate 2 H/L
Nm/deg
004
Rate 3 H/L
Nm/deg
005
1
ST
Time H/L
sec
006
2
ND
Time H/L
sec
007
Cycle Time
sec
008
Differential Angle H/L
deg
009
Fastening Result
reject
:
REJECT(Fastening NG)
accept
:
ACCEPT(Fastening OK)
abn
:
Stop by ABNORMAL(Abnormal occurs) signal
stop
:
Stop by loss of the STOP (Emergency Stop) Signal
reset
:
System clear by RESET(Reset) Signal
bypass
:
Stop by BYPASS(Bypass) Signal
st-off
:
START signal loss during BUSY (while operating) signal
010
1st NG item (The D-No. of the fastening NG item that occurred first is displayed)
011
Rate 1/2/3 judgment H/L
012
Fastening method (trq: torque method, ang: angle method, offset: offset check)
013
Number of fastening steps
014
Self-Check Flag (SC)
ON
:
Check Performed OFF
:
Check Not Performed
015
Reverse Flag (RV)
ON
:
Reversed OFF
:
Not reversed
016
Servo lock flag (SL)
ON: servo lock performed OFF: servo lock not performed
Nm
017
1
st
Peak Torque tq
Nm
018
2
nd
Peak Torque tq
Nm
019
SNUG Torque Judgment tq H
020
Final Torque (Offset Torque) tq H/L
Nm
021
Rate 1 Incremental Torque
Nm
022
Rate 1 Incremental Angle
deg
023
Rate 2 Incremental Torque
Nm
024
Rate 2 Incremental Angle
deg
025
Rate 3 Incremental Torque
Nm
026
Rate 3 Incremental Angle
deg
027
Peak Current during fastening H/L (Current High/Low Limit Warning Display)
A
028
Rundown Revolutions H/L
Rev.
029
Load Factor
%
030
Current (Amp) Value at the time when fastening is completed
A
031
Operation Sequence Number “—“ in the case of Single System or SLAVE
controller
032
Axis cycle count (×1 million)
* “--" if less than 1 million cycles
033
Axis cycle count (×1)
034
Tool cycle count (×1 million)
* “--" if less than 1 million cycles
035
Tool cycle count (×1)
Содержание AFC3000
Страница 1: ...AFC3000E HW 1 ...
Страница 17: ......
Страница 18: ...Chapter 1 Outline PAGE 1 1 Chapter 1 Outline 1 ...
Страница 25: ......
Страница 26: ...Chapter 2 Specifications PAGE 2 1 Chapter 2 Specifications 2 ...
Страница 34: ...Chapter 3 System Description PAGE 3 1 Chapter 3 System Description 3 ...
Страница 64: ...Chapter 4 Installation and Wiring PAGE 4 1 Chapter 4 Installation and Wiring 4 ...
Страница 131: ...Chapter 4 Installation and Wiring PAGE 4 68 Blank Page ...
Страница 132: ...Chapter 5 I O Expansion Unit Page 5 1 Chapter 5 I O Expansion Unit 5 ...
Страница 164: ...Chapter 6 Power up and Initial Checks PAGE 6 1 Chapter 6 Power Up and Initial Checks 6 ...
Страница 168: ...Chapter 7 Fastening Instructions PAGE 7 1 Chapter 7 Fastening Instructions 7 ...
Страница 207: ... Blank Page ...
Страница 208: ...Chapter 8 System Operation PAGE 8 1 Chapter 8 System Operation 8 ...
Страница 259: ...Chapter 8 System Operation PAGE 8 52 ...
Страница 260: ...Chapter 9 Maintenance Inspection PAGE 9 1 Chapter 9 Maintenance Inspection 9 ...
Страница 268: ...Chapter 10 Troubleshooting PAGE 10 1 Chapter 10 Troubleshooting 10 ...
Страница 294: ......