Chapter 4 Installation and Wiring
PAGE 4-63
4-10 External Emergency Stop Interface
The External Emergency Stop Interface is able to forcedly STOP a system by inputting an emergency
stop signal via the AUX connector on the bottom panel of the unit. This can be used in conjunction
with a FIELDBUS I/O interface to afford a hardwired option for the STOP signal.
The STOP signal function via the AUX. connector must be enabled by setting DIP
Switch SW2-1 ‘ON’.
Please refer to “Bottom Panel SW2 Switch Settings” Section 4-12-3.
Compatible Plug (STOP signal)
4-10-1 STOP Signal Specifications
Pin no
Signal
IN/OUT
Details
1
STOP+
IN
STOP signal input + (DC24V)
2
STOP-
IN
STOP signal input – (DC 0V)
●
Action when external STOP is ON with a Fieldbus Connection
At the point at which the external STOP signal is set to “OFF,” the fastening operation is stopped
and “STOP” is displayed in the upper section of the MFC display unit. Also, the PLC I/O output signal
“READY” turns “OFF.”
●
Action of External Emergency Stop Signal according to System/Communication mode
System Structure
・・・・
Communication Axis
Function
Single System
Acts on the Unit itself.
Multi System : MASTER Axis
Acts on the Units of all connected
spindles.
Multi System: SLAVE Axis
Acts on the Unit itself.
●
Output Circuit
Bidirectional Photo coupler PC354N1T (SHARP) or equivalent product
Input Voltage
11.4 to 26V * Recommended: 12V (5mA)/24V
(10mA)
Input Resistance
2.2K
Manufacturer: Phoenix Contact
Type: Cable connector
Model: MC 1,5/2-STF-3,81
Caution
Caution
Caution
Caution
Содержание AFC3000
Страница 1: ...AFC3000E HW 1 ...
Страница 17: ......
Страница 18: ...Chapter 1 Outline PAGE 1 1 Chapter 1 Outline 1 ...
Страница 25: ......
Страница 26: ...Chapter 2 Specifications PAGE 2 1 Chapter 2 Specifications 2 ...
Страница 34: ...Chapter 3 System Description PAGE 3 1 Chapter 3 System Description 3 ...
Страница 64: ...Chapter 4 Installation and Wiring PAGE 4 1 Chapter 4 Installation and Wiring 4 ...
Страница 131: ...Chapter 4 Installation and Wiring PAGE 4 68 Blank Page ...
Страница 132: ...Chapter 5 I O Expansion Unit Page 5 1 Chapter 5 I O Expansion Unit 5 ...
Страница 164: ...Chapter 6 Power up and Initial Checks PAGE 6 1 Chapter 6 Power Up and Initial Checks 6 ...
Страница 168: ...Chapter 7 Fastening Instructions PAGE 7 1 Chapter 7 Fastening Instructions 7 ...
Страница 207: ... Blank Page ...
Страница 208: ...Chapter 8 System Operation PAGE 8 1 Chapter 8 System Operation 8 ...
Страница 259: ...Chapter 8 System Operation PAGE 8 52 ...
Страница 260: ...Chapter 9 Maintenance Inspection PAGE 9 1 Chapter 9 Maintenance Inspection 9 ...
Страница 268: ...Chapter 10 Troubleshooting PAGE 10 1 Chapter 10 Troubleshooting 10 ...
Страница 294: ......