Chapter 8 System Operation
PAGE 8- 40
D-No.003
Judgment Item 1
Standard Setting
:
111101
Set the type of judgment for fastening.
00000
1
:
Peak Torque Check
・
Performs judgment if Peak Torque during fastening is within the High / Low limits.
0000
1
0
:
Final Torque Check
・
Performs judgment if Final Torque at the end of fastening is within the High / Low limits.
000
1
00
:
Final Angle Check
・
Performs judgment if Final Angle during fastening is within the High / Low limits.
The start point of angle measurement is D-No.107 [SNUG Torque].
00
1
000
:
1
st
Rate Check
・
Judges whether the slope of the torque rise between D-No.112 [1
st
Rate Start Torque]
~
D-No.113
[1
st
Rate End Torque] is within high/low limits.
0
1
0000
:
2
nd
Rate Check
・
Judges whether the slope of the torque rise between D-No.114 [2
nd
Rate Start Torque]
~
D-No.115
[2
nd
Rate End Torque] is within high/low limits.
1
00000
:
3
rd
Rate Check
・
Judges whether the slope of the torque rise between D-No.116 [3
rd
Rate Start Torque]
~
D-No.117
[3
rd
Rate End Torque] is within high/low limits.
D-No.004
Judgment Item 2
Standard Setting
:
000001
Set the type of judgment for fastening.
00000
1
:
Timeout Check
・
Judges whether the fastening time from fastening start to D-No.105 [1
st
Torque] or D-No.205 [1
st
Angle] OR from D-No.105 [1
st
Torque] or D-No.205 [1
st
Angle] to fastening end is within the Time (1st /
2
nd
) High / Low limits.
0000
1
0
:
Revolutions Check
・
Performs judgment if the revolutions during fastening is within the Rundown Revolutions High / Low
limits..
000
1
00
:
Differential Angle Check
・
Judges whether the DIFF Angle which is calculated by 2
nd
Rate and the final torque during
D-No.114 [2
nd
Rate Start Torque]
~
D-No.115[2
nd
Rate End Torque] is within high/low limits.
00
1
000
:
SNUG Torque Check
・
Judges whether the torque value when D-No.107 [SNUG Torque] is detected does not exceed the
Snug Torque high limit.
0
1
0000
:
Break Away Torque Check
・
Judges whether the peak reverse torque value during a reverse operation does not exceed the
Reverse Torque high limit.
1
00000
:
Torque Inhibit Check
・
Checks whether the torque value during the fastening operation at D-No.205[Torque Inhibit Angle] does
not exceed the Torque Inhibit high limit.
WARNING: Fastening judgment is NOT performed regardless of the values of
the high / low limit set values when the settings of the fastening parameters
D-No. 003 “Judge Item 1” and D-No. 004 “Judde Item 2” are DISABLED (0).
Cannot be disabled
Cannot be disabled
Cannot be disabled
Caution
Содержание AFC3000
Страница 1: ...AFC3000E HW 1 ...
Страница 17: ......
Страница 18: ...Chapter 1 Outline PAGE 1 1 Chapter 1 Outline 1 ...
Страница 25: ......
Страница 26: ...Chapter 2 Specifications PAGE 2 1 Chapter 2 Specifications 2 ...
Страница 34: ...Chapter 3 System Description PAGE 3 1 Chapter 3 System Description 3 ...
Страница 64: ...Chapter 4 Installation and Wiring PAGE 4 1 Chapter 4 Installation and Wiring 4 ...
Страница 131: ...Chapter 4 Installation and Wiring PAGE 4 68 Blank Page ...
Страница 132: ...Chapter 5 I O Expansion Unit Page 5 1 Chapter 5 I O Expansion Unit 5 ...
Страница 164: ...Chapter 6 Power up and Initial Checks PAGE 6 1 Chapter 6 Power Up and Initial Checks 6 ...
Страница 168: ...Chapter 7 Fastening Instructions PAGE 7 1 Chapter 7 Fastening Instructions 7 ...
Страница 207: ... Blank Page ...
Страница 208: ...Chapter 8 System Operation PAGE 8 1 Chapter 8 System Operation 8 ...
Страница 259: ...Chapter 8 System Operation PAGE 8 52 ...
Страница 260: ...Chapter 9 Maintenance Inspection PAGE 9 1 Chapter 9 Maintenance Inspection 9 ...
Страница 268: ...Chapter 10 Troubleshooting PAGE 10 1 Chapter 10 Troubleshooting 10 ...
Страница 294: ......