Chapter 5
I/O
Expansion Unit
Page 5-17
RATE1 LO REJ. No. # (1 to 32): Rate 1 Low Limit Signal of Spindle 1-32
The signal is set
“ON” if the value of rate 1 is below the fastening parameter D-No. 300 “Rate 1 Low
Limit.”
RATE2 HI REJ. No. # (1 to 32): Rate 2 High Limit Signal of Spindle 1-32
The signal is set
“ON” if the value of rate 2 exceeds the fastening parameter D-No. 303 “Rate 2 High
Limit.”
RATE2 LO REJ. No. # (1 to 32): Rate 2 Low Limit Signal of Spindle 1-32
The signal is set
“ON” if the value of rate 2 is below the fastening parameter D-No. 302 “Rate 2 Low
Limit.”
RATE3 HI REJ. No. # (1 to 32): Rate 3 High Limit Signal of Spindle 1-32
The signal is set
“ON” if the value of rate 3 exceeds the fastening parameter D-No. 305 “Rate 3 High
Limit
.”
RATE3 LO REJ. No. # (1 to 32): Rate 3 Low Limit Signal of Spindle 1-32
The signal is set
“ON” if the value of rate 3 is below the fastening parameter D-No. 304 “Rate 3 Low
Limit.”
NOTE:
The following output signals can be set in “PLC Output Layout” of the AFC3000 User
Console Software.
OUTPUT PORT (1 to 8): Output Signal Ports 1 to 8
These signals will output when the fastening sequence reaches a step that has a [PLC OUTPUT]
instruction inserted. Used to provide sequence operation status to external
PLC’s and/or control
outputs for slide motion, lights, & buzzers, etc without the use of a PLC. (The AFC User Console
Software can set these outputs on and off in the fastening sequence)
Also, the OUTPUT PORT signals are set
“OFF” under the following conditions;
When the START signal is ON
(“OFF”
→
“ON”)
When the REVERSE signal is ON
(“OFF”
→
“ON”)
When the RESET signal is “ON”
When the STOP signal is “ON”
During a transducer CAL or Zero Level check (Self Check)
TRQ. RCV No. # (1 to 32): Torque Hold Signal of Spindle 1-32
The signal is set “ON” if the value of the operation in D-No. 315 “Torque Recovery Time” is being
performed in the fastening operation.
PAR SELECT No. #(1 to 32): Parameter No. Return Signal (Individual)
Confirms the parameter number that is being used in the fastening operation.
PEAK TQ HI REJ. No. # (1 to 32): Peak Torque High Limit Signal of Spindle 1-32
The signal is set “ON” if the value of the peak torque exceeds the fastening parameter D-No. 102
“Peak Torque High Limit.”
Содержание AFC3000
Страница 1: ...AFC3000E HW 1 ...
Страница 17: ......
Страница 18: ...Chapter 1 Outline PAGE 1 1 Chapter 1 Outline 1 ...
Страница 25: ......
Страница 26: ...Chapter 2 Specifications PAGE 2 1 Chapter 2 Specifications 2 ...
Страница 34: ...Chapter 3 System Description PAGE 3 1 Chapter 3 System Description 3 ...
Страница 64: ...Chapter 4 Installation and Wiring PAGE 4 1 Chapter 4 Installation and Wiring 4 ...
Страница 131: ...Chapter 4 Installation and Wiring PAGE 4 68 Blank Page ...
Страница 132: ...Chapter 5 I O Expansion Unit Page 5 1 Chapter 5 I O Expansion Unit 5 ...
Страница 164: ...Chapter 6 Power up and Initial Checks PAGE 6 1 Chapter 6 Power Up and Initial Checks 6 ...
Страница 168: ...Chapter 7 Fastening Instructions PAGE 7 1 Chapter 7 Fastening Instructions 7 ...
Страница 207: ... Blank Page ...
Страница 208: ...Chapter 8 System Operation PAGE 8 1 Chapter 8 System Operation 8 ...
Страница 259: ...Chapter 8 System Operation PAGE 8 52 ...
Страница 260: ...Chapter 9 Maintenance Inspection PAGE 9 1 Chapter 9 Maintenance Inspection 9 ...
Страница 268: ...Chapter 10 Troubleshooting PAGE 10 1 Chapter 10 Troubleshooting 10 ...
Страница 294: ......