Chapter 8 System Operation
PAGE 8- 46
8-7-5 Fastening Parameters (Angle)
D-No.200 Final Angle Low Limit
[deg]
D-No.201 Final Angle High Limit
[deg]
Setting Range
:
0
~
9999.9
Set the high and low limits of fastening angle judgment.
If the fastening angle exceeds D-No.201 [Final Angle High Limit] or is lower than the D-No.200 [Final
Angle Low Limit], the fastening result will be REJECT
It is possible to detect the stretch or seizure of a bolt when it is fastened using these limits.
D-No.202
Standard Angle
[deg]
Setting Range
:
0
~
9999.9
Set the angle value of Standard Angle.
It is available only when D-No.000 [Fastening Type] is [Angle Control Method].
Ex.: When the Standard Angle is 10.0 and D-No.107 [SNUG Torque] is 0.0[deg], it fastens until the
fastening angle is reached to 10.0[deg].
D-No.203
1
ST
Angle
[deg]
Setting Range
:
0
~
9999.9
The angle value when the D-No.401 [Freerun Speed] or D-No.402 [1
ST
Speed] is shifted to D-No.402 [2
ND
Speed].
1
st
Angle is the end point of 1
st
Time and beginning of 2
nd
Time.
It is a synchronization point of the 1
st
STEP prior to commencing 2 STEP or 3 STEP fastening operations.
*Input the same value as D-No.201 [Final Angle High Limit] if the 1
ST
Angle is not used as a fastening
control.
D-No.204
2
ND
Angle
[deg]
Setting Range
:
0
~
9999.9
The angle value that the speed is shifted from D-No.402 [2
nd
Speed] to D-No.403 [3
rd
Speed].
It is a synchronization point of 2
nd
STEP for prior to commencing a 3 STEP fastening operation.
*Input the value higher than D-No.201 [Final Angle High Limit] if the 2
ND
Angle is not used as a fastening
control.
D-No.205
Torque Inhibit Angle
[deg]
Setting Range
:
0
~
9999.9
Set the angle that conducts the starting torque cut from the point of fastening start.
*The Torque Inhibit check is not conducted when the Torque Inhibit Check is enabled and [0] is set as
Torque Inhibit Angle.
D-No.206
Differ Angle
[deg]
D-No.207
Differential - Angle
[deg]
Setting Range
:
-999.9
~
999.9
Set the high and low limits to conduct the Differential Angle Check.
Differential Angle (difference) is judged by the 2
ND
Rate and the Final Torque regardless of the fastening
method.
Содержание AFC3000
Страница 1: ...AFC3000E HW 1 ...
Страница 17: ......
Страница 18: ...Chapter 1 Outline PAGE 1 1 Chapter 1 Outline 1 ...
Страница 25: ......
Страница 26: ...Chapter 2 Specifications PAGE 2 1 Chapter 2 Specifications 2 ...
Страница 34: ...Chapter 3 System Description PAGE 3 1 Chapter 3 System Description 3 ...
Страница 64: ...Chapter 4 Installation and Wiring PAGE 4 1 Chapter 4 Installation and Wiring 4 ...
Страница 131: ...Chapter 4 Installation and Wiring PAGE 4 68 Blank Page ...
Страница 132: ...Chapter 5 I O Expansion Unit Page 5 1 Chapter 5 I O Expansion Unit 5 ...
Страница 164: ...Chapter 6 Power up and Initial Checks PAGE 6 1 Chapter 6 Power Up and Initial Checks 6 ...
Страница 168: ...Chapter 7 Fastening Instructions PAGE 7 1 Chapter 7 Fastening Instructions 7 ...
Страница 207: ... Blank Page ...
Страница 208: ...Chapter 8 System Operation PAGE 8 1 Chapter 8 System Operation 8 ...
Страница 259: ...Chapter 8 System Operation PAGE 8 52 ...
Страница 260: ...Chapter 9 Maintenance Inspection PAGE 9 1 Chapter 9 Maintenance Inspection 9 ...
Страница 268: ...Chapter 10 Troubleshooting PAGE 10 1 Chapter 10 Troubleshooting 10 ...
Страница 294: ......